3.6
Details of quality adjustment items
3
Press [Gamma Automatic Adj.] and press [OK].
4
Press [Exit [ADJUSTMENT]].
Wait until the message [Now adjusting] on the screen disappears.
3.6.3
[Density Balance Adjustment] (for i1Pro, i1Pro2, or i1iSisXL)
To not continuously perform the series of adjustment of the image quality adjustment flow, perform page 3-9,
and then resume from the next adjustment.
Image quality adjust-
ment flow
Adjustment flow when
changing the screen
Regular adjustment
flow: Normal
Regular adjustment
flow: High Precision
d
Reference
You can register measurement data (density balance adjustment value) on the machine after the color density
control has been completed. For details, refer to page 3-32.
A dedicated application is required to measure test charts. The application varies depending on your spec-
trophotometer. For i1-Pro, i1-Pro2, or i1iSisXL, use X-rite Measure Tool. Install the tool in advance.
AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L
Position of this adjustment
Previous adjustment
Gamma Automatic Ad-
justment
- (None)
- (None)
This adjustment
This adjustment
3
Next adjustment
Color density control
3-11