Serial Communications; Rs-232 Connection And Port Configuration; Serial Command Syntax - Runco Video Xtreme VX-2000d Operating Manual

1080p digital light processing projector and digital high definition (dhd) controller
Hide thumbs Also See for RUNCO Video Xtreme VX-2000d:
Table of Contents

Advertisement

To interface the DHD Controller with a home theater automation/control system or a PC
running terminal emulation software, connect it to your control system or PC as shown in
Figure 3-11.
Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop
bit and no flow control. Set the baud rate to 19200, to match that of the DHD Controller
RS-232 port.
Serial commands to the DHD Controller take the following form:
• Commands are not case-sensitive.
• For a single command that takes no parameters, type the command followed by a
carriage return; for example, to set the aspect ratio to Letterbox, type
LETTERBOX <Enter>.
• For a single command that takes a parameter, type the command, a space or a
comma and the desired value followed by a carriage return; for example, to set the
brightness to -10, type BRIGHTNESS -10 <Enter> or
BRIGHTNESS,-10 <Enter>.
• You can also send a string of multiple commands on a single line, separated by
commas. For example, COMPOSITE,BRIGHTNESS 100,ANAMORPHIC <Enter>
switches to the Composite video input, sets the brightness to 100 and sets the aspect
ratio to Anamorphic. Command strings can be up to 255 characters long.
Avoid combining the ON or POWER 1 commands with other commands
Note
on a single line. After sending ON or POWER 1, allow at least 15
seconds for the DHD Controller to power up. Once it does, it will accept
and properly execute multiple serial commands.
Table 6-1 lists the RS-232 command set. The "Parameter (min/max)" column shows the
valid parameter ranges, or "NA" for commands that take no parameters.
When you enter a valid command, the DHD Controller executes it and acknowledges it
with a plus sign on the command line (+ >). When you enter an invalid command – one
that is misspelled or followed by values outside the valid range for that command – the
DHD Controller ignores it and returns a minus sign (- >).
Table 6-1. Serial Commands
Parameter
Command
(min/max)
OFF
NA
ON
NA
POWER
0/1
POWER?
NA
Runco VX-2000d Owner's Operating Manual
Value
Stored?
Power On/Off Commands
NA
Turns projector off
NA
Turns projector on
NA
Turns projector on and off
NA
Returns power status

6. Serial Communications

Description
67
6.1
RS-232 Connection
and Port Configuration
6.2
Serial Command
Syntax