Technical Product Specification
Pin
7
8
9
10
11
12
13
14
15
6.4.3 NIC Connectors
The server board provides three independent RJ-45 connectors on the back edge of the
board. The pin-outs for NIC connectors are identical and are defined in the following table.
6.4.4 SATA Connectors
The server board provides five SATA port connectors from SATA_0 to SATA_3 ports and
SATA DOM support on board. Additional four SATA ports are provided through the bridge
board.
The pin configuration for each connector is identical and defined in the following table.
Revision 1.37
Signal Name
GND
GND
P5V
GND
NC
V_IO_DDCDAT
V_IO_HSYNC_CONN
V_IO_VSYNC_CONN
V_IO_DDCCLK
Table 32. RJ-45 10/100/1000 NIC Connector
Pin
1
LED_NIC_LINK0_100_N
2
LED_NIC_LINK0_1000_R_N
3
NIC_0_0_DP
4
NIC_0_0_DN
5
NIC_0_1_DP
6
NIC_0_1_DN
7
NIC_CT1
8
NIC_CT2
9
NIC_0_2_DP
10
NIC_0_2_DN
11
NIC_0_3_DP
12
NIC_0_3_DN
13
LED_NIC_LINK0_LNKUP_N
14
LED_NIC_LINK0_ACT_R_N
Description
Ground
Ground
No fuse protection
Ground
No connection
DDCDAT
HSYNC (horizontal sync)
VSYNC (vertical sync)
DDCCLK
Signal Name
Connector and Header
79