6
Inspection and maintanance
6.13

Remove the heating pump

1. Unplug the plug.
2. Remove screws.
3. Pull out the pump head towards the front.
1.
3.
Fig. 25
6.14

Removing the motor of the 3-way valve

1. Undo clip.
2. Remove the motor of the 3-way valve.
1.
Fig. 26
B Press the cable restraint and remove the plug.
6.15

Remove the heat exchanger

B Remove suction line and mixer unit.
B Remove the fan.
1. Remove the clip.
2. Remove the flow pipe.
3. Remove the cable from the flue gas temperature limiter
52
2.
0 010 006 639-002
2.
0 010 006 640-002
4. Remove the nut
2.
3.
Fig. 27 Remove the flow pipe and disconnect the cable
1. Unclip the vent pipe and push it upwards.
2. Rotate the vent pipe clockwise.
3. Remove the heat exchanger
2.
1.
Fig. 28 Remove the heat exchanger
1.
4.
0 010 005 852-001
3.
0 010 005 853-001
Logamax Plus GB062