3
Service menu settings
3.2.3
Menu 3
To call up a service function in this menu:
B Hold down "Back", + and – at the same time until L.1 is
shown on the display.
Service function
E.1
Appliance type, output, DHW heat-
ing (soft code)
F.1
Gas Type
Tab. 5
Menu 3
Code List for the Service function E.1 :
Country
Definition of Appliance
TR (Turkey)
GB062-22 KD ...
IT (Italy)
GB062-24 (K) .....
GB062-24 KD ...
AT (Austria)
GB062-24 (K) ...
PL (Poland)
GB062-24 (K) ...
RO (Romania)
GB062-24 KD ....
GR (Greece)
GB062-24 KD ...
SK (Slovakai)
GB062-24 (K) ....
CZ (Czech
GB062-24 (K) ....
Repuclic)
BE (Belgium)
GB062-24 KDE ....
GB062-24 KD ...
Tab. 6
Code table for the service function E.1
14
Possible settings/comments/displays
This service function allows you to adjust the control unit to the appliance
output and the type of DHW heating (see table below regarding the code list
for this service function). This is only necessary when the control unit is
replaced.
With this service functlon is changed the gas type.
B To change the actual gas type, press + and - button together until the
scroll up/down symbol is shon in display.
• 0 : Naturalgas
• 1 : Liquidgas (LPG)
Soft
Code
GB062-14 ...
GB062-14 ...
GB062-24 ....
GB062-24 ....
GB062-14 ....
GB062-14 ....
GB062-14 ....
GB062-24 ....
B Press – until L.3 is shown on the display.
B Press OK to make settings in menu 3.
B Press + or – to scroll through the menu's service
functions.
This parameter is only available/active for the
spare part change. By origin PCB (electronic
card) this function is only visible.
This parameter should be adjusted by each
21
PCB-Change regarding the TTNr. (Codelist is in
PCB included).
22
23
24
22
27
29
27
28
27
28
27
29
27
29
28
26
30
25
Logamax Plus GB062