Buderus Logamax GB062-24 KDE H V2 Service Manual page 35

Logamax plus gb062 series; gb062-14 series; gb062-24 series; gb062-22 kd series; gb062-24 kd series; gb062-24 kde series; gb062-24 (k) series; gas wallhung boiler
Table of Contents

Advertisement

EC
Internal fault (Internal fault in the program sequence or failure of the mains voltage).
Step
1.
Is blinking error code in display ?
2.
B Switch off the boiler.
B Is the ignition cable connection loose
or damaged ?
3.
Check the O2 CO values at min. and
max. Are the values correct ?
B Switch off the boiler.
4.
B Cut the main voltage supply.
B Is there any damage on securty
valve (gas valve) or connection
cable?
5.
Electronic board (PCB) is defect.
Logamax PLus GB062
Remedy
yes:
B Reset the boiler and restart the boiler again.
EC ? --> 2.
no:
--> 2.
yes:
B Change the ignition cable and the connection or if
possible fix it.
B Switch on the boiler.
EC ? --> 3.
no:
--> 3.
yes:
--> 4.
B Correct he adjustment.
no:
EC ? --> 4.
B Change the connection cable to securty valve.
yes:
B Switch on the boiler.
EC? --> 5.
no:
--> 5.
B Switch off the boiler.
B Cut the main voltage supply.
B Change the electronic board (PCB)
B Switch on the main voltage supply.
B Switch on the boiler.
B END.