Buderus Logamax GB062-24 KDE H V2 Service Manual page 10

Logamax plus gb062 series; gb062-14 series; gb062-24 series; gb062-22 kd series; gb062-24 kd series; gb062-24 kde series; gb062-24 (k) series; gas wallhung boiler
Table of Contents

Advertisement

3
Service menu settings
Service function
4.b
max pre heat temperature for
comfort function (combi)
4.E
Boiler type
4.F
Siphon filling mode
5.A
Reset service reminder
5.b
Fan overrun time
5.F
Inspection intervall
6.A
Calling up the last fault saved
6.C
Setpoint value of the tempera-
ture from EMS-BUS
6.d
Current turbine flow rate (combi)
7.A
Backlight of LCD
7.C
Minimum DHW flow rate
Tab. 3
Menu 1
10
Possible settings/display
max DHW pre heat temperature for comfort function.
The following settings are possible:
• 40 ... 65 ºC
Default setting : 62 º
It will be detected automaticly of DHW or tank NTC and shown in display.
Possible values:
• 0 : only heating
• 1 : Combi
• 2 : Tank with NTC (system boiler)
Possible settings:
• 0 : Off
• 1 : On with min output (factory setting)
• 2 : On with changed min CH output
If you see this symbol, you can reset to "0" after inspection.
Time intervall for the maintanence (month)
0 = Off
1 .. 72 = Time (Month)
If you see this symbol, you can reset to "0" after inspection.
The function enables you to retrieve the last fault stored.
The service function is reset at 00.
The current turbine flow rate is displayed.
Possible displays are:
• 0.0. - 20.0. l/min
The following settings are possible:
• 00: Off
• 01: on
Default setting : 00.
DHW heating is activated if amounts above this value are drawn off.
The following settings are possible (x 0,1):
• 25 ... 50 litres per minute
Default setting : 25 l/min.
Logamax Plus GB062