Servicing; Terminal Voltage For Each Part During Normal Periods (No-Load Periods); Stator Coil - Kubota GL6000 Workshop Manual

Diesel generator
Table of Contents

Advertisement

GL6000, GL7000, GL9000, GL11000, WSM

[3] SERVICING

(1) Terminal Voltage for Each Part During Normal Periods (No-load Periods)

(2) Stator Coil

Output Terminal
1. With the NFB in the ON position, measure the voltage in each
phase and each line.
2. If the factory specification is not indicated, inspect the output
circuit or the wiring harness.
(Refer to "5. WIRING DIAGRAM" (2-M8).)
Output voltage
Factory spec.
[A] Terminal Type
Main Coil Winding
1. Test for continuity between coil leads with a milliohm meter.
Many kind of wiring have been arranged in the stator depending
on the voltage variation.
2. If the resistance is not as specified, replace the stator or contact
service station.
(Refer to "5. WIRING DIAGRAM" (2-M8).)
Resistance
Factory spec.
* Measurement is not possible with a regular tester.
[A] G6000, GL7000
2-S20
GENERATOR
Rated voltage 7 or 8 %
[B] Receptacle Type
W1068933
Refer to "2. SERVICING
SPECIFICATION" (2-S6).
[B] GL9000, GL11000
W1026118
KiSC issued 05, 2015 A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gl7000Gl9000Gl11000

Table of Contents