About These Installation Instructions; Product Information; Intended Use - Viessmann Vitosol 100-FM SV1F Installation, Operating And Service Instructions

Flat plate solar collectors for sloped roofs, flat roofs, walls and freestanding installation
Table of Contents

Advertisement

Vitosol 100-FM/200-FM Installation, Operating and Service

About these Installation Instructions

Take note of all symbols and notations intended to draw attention to potential hazards or important product
information. These include "WARNING", "CAUTION", and "IMPORTANT". See below.
WARNING
Indicates an imminently hazardous situation which,
if not avoided, could result in death, serious injury
or substantial product/property damage.
CAUTION
Indicates an imminently hazardous situation which,
if not avoided, may result in minor injury or product/
property damage.
IMPORTANT

Product Information

Intended Use

The appliance is only intended to be installed and
operated in sealed pressurized systems with due attention
paid to these instructions.
DHW tanks are only designed to store and heat water
of potable water quality. Heating water buffer tanks are
only designed to hold fill water of potable water quality.
Only operate solar collectors with the heat transfer
medium approved by the manufacturer. Intended use
assumes that a fixed installation in conjunction with
permissible, system-specific components has been carried
out.
Warnings draw your attention to the presence of
potential hazards or important product information.
 Cautions draw your attention to the presence of
potential hazards or important product information.
 Helpful hints for installation, operation or maintenance
which pertain to the product.
 This symbol indicates that additional, pertinent
information is to be found.
 This symbol indicates that other instructions must
be referenced.
Refer to the Vitosol 100-FM and Vitosol 200-FM
Technical Data Manuals for complete technical
information and product description.
Vitosol 100-FM, Models SV1F, SH1F
Vitosol 200-FM, Models SV2F, SH2F
Flat plate solar collector
Absorber area:
Max. stagnation temperature: 293°F (145°C)
Max. operating pressure:
Commercial or industrial usage for a purpose other
than heating the building or DHW shall be deemed
inappropriate.
Any usage beyond this must be approved by the
manufacturer for the individual case.
Incorrect usage or operation of the appliance (e.g. the
appliance being opened by the system user) is prohibited
and results in an exclusion of liability.
Incorrect usage also occurs if the components in the
system are modified from their intended use (e.g.
through direct DHW heating in the collector).
Adhere to statutory regulations, especially concerning
the hygiene of potable water.
General Information
25 ft
2
(2.3 m
2
)
87 psig (6 bar)
5