Specifications

Electrical
Each ice machine requires its own separate circuit with electrical disconnect within 10 ft (6m).
Equipment ground required.
Standard electrical:
§ 115 V/60/1 (6 ft (2m) NEMA 5-15 cord and plug provided)
§ Amperage: 11.3A, dedicated 15A circuit required
Plumbing
This equipment to be installed with adequate backflow protection to comply with applicable federal, state,
and local codes.
§ 3/8" OD push-in water inlet (connection inside machine) - 3/8" OD tubing required
§ 3/4" MPT drain
Notes:
§ Water shut-off recommended within 10 feet (3m).
§ Water supply must have particle filtration. Follett recommends the filter system that has integral scale inhibitors.
(Follett item# 00130286).
§ Follett does not recommend the use of water softeners or bowl scale inhibitors.
Drain plumbing
§ 3/4" MPT drain connection at the rear of the machine.
§ Drain must slope 1/4" inch per foot (6 mm per 30.4 cm).
§ Drain line should not be shared with any other piece of equipment.
§ Drain line cannot be reduced to a size smaller than 1 inch.
§ Drain should be piped without a vent.
2 ft. x 1" OD
silicone tubing
(6,4 mm per 0,3 m)
4
3/4" barb x 3/4" FPT
3/4" MPT x 1" slip
1/4" per foot
1'
WARNING
1" PVC Drain
3/4" barb x 3/4" FPT
Minimum 8"
radius
2 ft. x 1" OD
silicone tubing
3/4" MPT x 1" slip
1" Stand pipe/Drain
HCD710A, HMD710A