Ranger 9000E Installation Manual page 50

Downloadable control communicator
Table of Contents

Advertisement

This document lists the event reporting codes for Ademco Contact ID reporting. The event codes are programmed
by placing a number from 0-15 in the Data 1 location of the communicator code for the event being reported. For
zones, programming a "0" as the Data 1 location will result in an automatic selection of the event code depending
on the zone type choosing from Fire, Panic, and Burglary. The Data 2 and Data 3 are sent as the Zone Identifier.
PROGRAMMED DATA 1
0
1
2
3
4
5
6
7
8
9
10
11
12
If the following numbers are programmed for the Contact ID event code, the event code will be made up of 3
alternate programming locations according to the following:
PROGRAMMED DATA 1
13
14
15
The following event codes are sent automatically, but must be enabled by programming a 1 in the communicator
code location for that report:
REPORTING EVENT
Keypad Tamper
Autotest
Opening/Closing
Cancel
A.C. Loss
A.C. Restore
Restore
Zone Bypass
Zone Trouble
Low Battery
Battery Restore
Battery Test Fail
Battery Test Restore
Late to Close
Early to Open
Download Complete
Expander Module Trouble
Expander Trouble Restore
RF Loss of Supervision
RF Transmitter Low Battery
APPENDIX 2
ADEMCO EVENT CODE
122
110
120
130
131
132
133
134
135
150
121
100
123
PROGRAMMING LOCATIONS
365,366,367
369,370,371
373,374,375
ADEMCO EVENT DIGIT
137
602
401
406
301
301
Event code for alarm
570
380
302
302
309
309
404
400
412
333
333
381
384
50
DEFINITION
Silent Panic (Only for Loc. 332)
Fire
Panic
Burglary
Perimeter Burglary
Interior Burglary
24 hour Burglary
Entry/Exit Burglary
Day/Night Burglary
Non-burg 24 hour
Duress
Medical Alarm
Audible Panic
LOCATIONS
336
340
348 / 350
354
356
376
364
368
372
360
376
360 / 255
376
592
588
596
378
511
(For these two, see
9090 Installation Manual)

Hide quick links:

Advertisement

Table of Contents
loading