Locations 412-427: Assigning Audible Characteristics For Zones 17-32
Locations 412-427 are used to assign the Audible Characteristics for zones 17 through 32. Location 412
corresponds to zone 17, and location 427 corresponds to zone 32. To determine the appropriate data for these
locations, refer to the chart below and add the sum of the corresponding values to arrive at the correct data for
these locations. Zones 17-32 have a factory default setting of "13" (1+ 4 + 8 = "13"). This means that zones 17-32
will create a yelp siren output and a keypad sounder output when an alarm is created. To select the audible
characteristics for any zone, add the values of the audible characteristics from the table below, and program the
sum in the appropriate locations 412-427. NOTE: If a Fire zone type is selected in locations 380-395, standard
fire zone characteristics will override any selection made for a zone in this section. If you wish for the zone to be
SILENT, program a "0" in the appropriate location.
Locations 428-443: Special Communicator Reporting Characteristics For Zones 17-32
Locations 428-443 are used to assign communicator characteristics to individual zones 17 through 32. Location
428 is for zone 17 and location 443 is for zone 32. Each zone can have one, or any combination of these
characteristics. Factory default for all zones is "11" (1 + 2 + 8 ="11"). This means that each zone has RESTORE
REPORTING (Value=1), BYPASS REPORTING (Value=2), and REPORT CANCELING (Value=8) enabled. It
should be noted that these locations are used to enable individual zone report capability by zone. A reporting code
must be programmed in the appropriate location to enable overall reporting capability of Restore reports (location
364), Bypass reports (location 368), Trouble/24 Hour Tamper reports (location 372), and Cancel reports (location
354).
VALUE
AUDIBLE CHARACTERISTICS
Silent
0
1
Yelp Siren Audible
2
Steady Siren Audible
Keypad Sounder Audible
4
Chime Enable
8
VALUE
REPORTING CHARACTERISTICS
Restore Reporting
1
Bypass Reporting
2
4
Trouble/24 Hour Tamper Reporting
8
Report Canceling
31