Location 246: Common Area Enable
If a "1" is programmed in location 246, Partition 1 will become a Common Area for all selected partitions. When
enabled, Partition 1 will automatically disarm when any other partition is disarmed, and will automatically arm when
all partitions have been armed (cannot be armed or disarmed independently). Care should be taken to allow
sufficient entry delay time for Partition 1 to allow the user to reach his designated partition keypad and enter a code.
Exit delay time is the delay for the last partition to arm. Factory default is "0" and this feature is disabled.
Location 247: Number Of Zones In Partition 1
Factory default is "0", and the control is not partitioned. Thus, all 16 (32 if expander is utilized) are assigned to the
one group. NOTE: When no partitions are enabled, all features or characteristics associated with partitions are
contained within one group.
Location 248: Number Of Zones In Partition 2
Factory default is "0", and Partition 3 is not enabled.
Location 249: Number Of Zones In Partition 3
Factory default is "0", and Partition 4 is not enabled.
Location 250: Power Up Condition
If a "1" is programmed in location 250 , the Ranger 9000E will power-up disarmed if there is a total power shutdown
and battery failure. If a "2" is programmed in this location, it will power-up armed. If this location contains a "0", the
Ranger 9000E will maintain the condition it was in at power-down. A watchdog circuit reset will cause the Ranger
9000E to reset to the selected condition. Factory default is "0" and the control will maintain the condition it was in
at power-down.
Location 251: Power Up Delay
The number programmed in location 251 represents the number of 10 second increments the Ranger 9000E will
delay before accepting open or short inputs from any zone. Factory default is "0" and this feature is disabled. If a
6 is selected, the delay will be 60 seconds. This delay period would also be initiated after a watchdog circuit reset
condition or when exiting from the program mode.