Ranger 9000E Installation Manual page 28

Downloadable control communicator
Table of Contents

Advertisement

Locations 350: Communicator Code To Report Closings For Users 1-15
The Ranger 9000E has the ability to report a closing code each time the control is armed. The desired closing code
is programmed in this location. If this location contains a "0", closings will not be reported. The number programmed
in this location is sent first. The second digit is automatically the user number. When using Auto Arm the user
number is 28. When using the Quick Arm digit, the user number is 29. When using a keyswitch, the user number
is 30. The closing report will not be initiated until the end of the exit delay.
Location 351: Select Phone #1, 2, Internal Log, Or Any Combination To Report Closings For Users 1-15
(See Location 259)
Location 352: Communicator Code To Report Closings For Users 16-30
This location will be programmed only when using a 4 + 2, or extended format.
Location 353: Communicator Code To Report Openings For Users 16-30
This location will be programmed only when using a 4 + 2, or extended format.
Location 354: Communicator Code To Report Cancel (Exception Opening) For Users 1-15
Location 354 contains the communicator code that will be sent to identify users numbered 1-15 for Cancel. The
Cancel code programmed in this location will be sent if an arm/disarm code is entered after a trip on any zone has
been reported (excluding Fire zones). After a cancel has been reported, no loop restorals will be transmitted on
non-24 Hour zones. The number programmed in this location is sent first. The second digit is automatically the user
number. If this location contains a "0", Cancel is disabled. (When using a key switch, the user # is 30.)
Location 355: Communicator Code To Report Cancel (Exception Opening) For Users 16-30
This location will be programmed only when using a 4 + 2, or extended format.
Locations 356-358: Communicator Code For Reporting AC Power Loss
The Ranger 9000E has the ability to report an AC Power Loss code after the AC power has been off for a selected
number of minutes from 0 to 15 (see location 623). The desired 1 to 3 digit AC failure code is programmed in these
locations. If all locations are "0", AC Power Loss will not be reported.
Location 359: Select Phone #1, 2, Internal Log, Or Combination To Report AC Power Loss (See Location 259)
Location 360-362: Communicator Code For Reporting Low Battery
The Ranger 9000E has the ability to report a Low Battery code when AC power has been lost and the battery has
discharged down to 10.3 volts. The desired 1 to 3 digit Low Battery code is programmed in these locations. If all
locations are "0", Low Battery will not be reported.
Location 363: Select Phone #1, 2, Internal Log, Or Combination For Reporting Low Battery (See Location 259)
The following locations allow for transmitting variable Restore report codes in zone blocks of 8. If a code
is selected for zones 1-8 in location 364 it will apply to all zones unless individual codes are selected in
locations 365-367. If location 364 is "0" no zone restorals will be reported. If locations 365-367 are "0", the
code in location 364 will be sent.
Location 364: Restore Code For Zones 1 Thru 8
Location 365: Restore Code For Zones 9 Thru 16
Location 366: Restore Code For Zones 17 Thru 24 (When Using Expansion System)
Location 367: Restore Code For Zones 25 Thru 32 (When Using Expansion System)