Data 1 (Source) -
DATA 2 (Duration) -
DATA 3 (Category) - The number programmed in the Data 3 location will determine the category from which you
DATA 4 (Event) -
The number programmed in the Data 1 location is used to direct the control as to which
individual partition, or group of partitions will activate the trigger output to the four auxiliary
outputs. Simply refer to the chart below to select the partition(s) and program the correct
number (0-14) in the DATA 1 location of the output being programmed. If partitioning is not
being used, program a "0" in the DATA 1 location of the selected output for activation from
all zones. Factory default is "0", for all Partitions.
DATA
"0"
All Partitions
"1"
Partition 1
"2"
Partition 2
"3"
Partition 1 and 2
"4"
Partition 3
"5"
Partition 1 and 3
"6"
Partition 2 and 3
"7"
Partition 1, 2, and 3
"8"
Partition 4
"9"
Partition 1 and 4
"10"
Partition 2 and 4
"11"
Partition 1, 2, and 4
"12"
Partition 3 and 4
"13"
Partition 1, 3, and 4
"14"
Partition 2, 3, and 4
The number programmed in the Data 2 location represents the amount of time that a trigger
output will remain activated. This duration time is selectable in 2 second increments, from
2 to 28 seconds. For example, programming a "5" in the data 2 location will create a voltage
trigger that would last for 10 seconds (2 x "5" = 10 seconds). Programming a "0" will cause
the output to follow the condition. Programming a "15" will latch the trigger output.
Programming selections for this location are the numbers "0" thru "15". NOTE: If you want
to change the increments from seconds to minutes, follow the programming instructions for
location 241 to do so, and the duration time will be selectable from 1 to 14 minutes.
will select an activation event. Refer to the following table on pages 19 and 20 to select
which category number to program in this location. Programming selections for this location
are "0" thru "15".
The number programmed in the Data 4 location will determine the actual event in which you
wish to have the trigger activate upon. Refer to the table on pages 19 and 20 to select which
event number to program in this location. Programming selections for this location are "0"
thru "15".
PARTITIONS ENABLED
18