Network Setup (Rs 485 With Panel Mounting Kit); Operating Instructions Issue - Siemens AOP Operating Instructions Manual

Hide thumbs Also See for AOP:
Table of Contents

Advertisement

14.
Press
15.
Set P0700 = 4 (AOP).
16.
Press
17.
Using
18.
Set P1000 = 1 (MOP Setpoint).
19.
Using
20.
Press
21.
Set P0010 access level to 0
22.
Press
23.
Press
24.
Press
25.
Press
26.
Using
27.
Using
28.
Press
Note
If the AOP is to be used as the normal control means for the
inverter it is recommended that the user Set P2014.1 = 5000. To
do this first set P0003 = 3. This setting will cause the drive to trip if
communication with the control source, the AOP, is lost.
If you have problems connecting to the inverters – set the Auto
Baud to OFF and the default baud rate to the same as the
inverter. See Section 2.5 on page 10.
2.2

Network Setup (RS 485 With Panel Mounting Kit)

There are two main modes of operation for the AOP when connected to a
network of Micromaster 4
Master mode of operation on the AOP allowing a single drive to be accessed on
the network with full control/parameter access or selecting B or broadcast mode
all drives on the network can be set to start/stop at the same time.
The AOP has the capability to control up to 31 inverters connected as a network.
A unique two-digit number identifies each inverter.
To set-up a network of inverters under the control of an AOP, the following
procedure should be performed:
AOP Operating Instructions – Issue 07/05
6SE6400-5AP00-0BB0
to edit the parameter value.
to confirm selection.
and
select P1000.
and
select P0010
to edit the parameter value.
to confirm selection.
to return to r0000.
to display the standard screen.
to start the inverter/motor.
the output will increase
the output will decrease
to stop the inverter/motor.
th
generation drive. These modes are both under the
5