Siemens SINAUT MD741-1 System Manual page 84

Simatic net egprs/gprs-router
Hide thumbs Also See for SINAUT MD741-1:
Table of Contents

Advertisement

VPN connection
DPD - timeout (seconds)
Time period in seconds after which the connection to the remote station will be
declared dead if no response has been made to the DPD requests.
DPD – maximum failures
Number of failed attempts permitted before the IPsec connection is considered to
be interrupted.
Factory setting
The factory settings for the SINAUT MD741-1 are as follows:
Name
Enabled
Authentication method
Remote ID
Local ID
Remote certificate
Wait for remote connection
Remote net address
Remote subnet mask
Local net address
Local subnet subnet mask
ISAKMP-SA encryption
IPsec-SA encryption
ISAKMP-SA hash
IPsec-SA hash
DH/PFS group
ISAKMP-SA mode
ISAKMP-SA lifetime (seconds)
IPsec-SA lifetime (seconds)
NAT-T
84
NewConnection
No (switched off)
CA certificate
NONE
NONE
-
No
192.168.2.1
255.255.255.0
192.168.1.1
255.255.255.0
3DES-168
3DES-168
MD5
MD5
DH-2 1024
Main
86400
86400
On
C79000- G8976-C212
SINAUT MD741-1

Hide quick links:

Advertisement