Siemens SINAUT MD741-1 System Manual page 65

Simatic net egprs/gprs-router
Hide thumbs Also See for SINAUT MD741-1:
Table of Contents

Advertisement

External ICMP to the SINAUT MD741-1
You can use this option to affect the response when ICMP packets are received
that are sent from the external network in the direction of the SINAUT MD741-1.
You have the following options:
Drop: All ICMP packets to the SINAUT MD741-1 are discarded.
Allow Ping: Only ping packets (ICMP type 8) to the SINAUT MD741-1 are
accepted.
Accept: All types of ICMP packets to the SINAUT MD741-1 are accepted.
Factory setting
The factory settings for the SINAUT MD741-1 are as follows:
Maximum number of parallel connections
Maximum number of new incoming TCP
connections per second
Maximum number of new outgoing TCP
connections per second
Maximum number of new incoming ping
packets per second
Maximum number of new outgoing ping
packets per second
External ICMP to the MD741-1
SINAUT MD741-1
C79000- G8976-C212
Security functions
4096
25
75
3
5
Drop
65