How To Change The Speed Reference (Non-Imo Types Only); Sensor Menu; Other Menu - Furuno SC-130 Operator's Manual

Satellite compass
Table of Contents

Advertisement

2.15.6

How to change the speed reference (Non-IMO types only)

The speed reference is used in the VHW sentence for speed data output to external
equipment.
1. Open the [MENU].
2. Select [I/O], then press the ENT key.
3. Select [MISCELLANEOUS], then press the ENT key.
4. Select [STW] (Speed Through Water), then press the ENT key. An options pop up
window appears.
5. Select [AUTO] or [MANUAL] as appropriate, then press the ENT key.
[VECTOR] : Speed is calculated based on own ship vector.
[SCALAR]
6. Close the [MENU].
2.16

SENSOR Menu

The [SENSOR] menu contains settings for the connected sen-
sors. Some settings in this menu require service level access and
are not changeable by the user.
To access this menu, open the [MENU], then select [SENSOR].
Note: The [OFFSET] menu is reserved for technical personnel only.
2.16.1

OTHER menu

1. Open the [MENU].
2. Select [SENSOR], then press the ENT key.
3. Select [OTHER], then press the ENT key.
4. Select the appropriate menu item, then press the ENT key.
• [GNSS RESTART]: Restarts the GNSS cores. A confirmation message ap-
pears; select [YES] to reset the GNSS cores or select [NO] to cancel the reset.
• [DR TIME]: Set the Dead Reckoning time. Available options are [1 min], [2 min],
[3 min], [4 min] and [5 min] (default setting). Select the required time, then press
the ENT key.
• [MAGNETIC VARIATION]: Select whether to
adjust for magnetic variation automatically
([AUTO]) or manually ([MANUAL]). If you se-
lected [MANUAL], the [INPUT MAGNETIC
VARIATION] pop up window appears. Enter
the variation amount, select [ENTER], then press the ENT key.
Note: The [MAGNETIC VARIATION] menu item is not available for IMO types.
5. Close the [MENU].
: Speed is calculated based on SOG (Speed Over Ground).
For technical personnel
only
Not available for IMO types