D I SPLAYED I TEM
RI BBON LOW OPTI ONS
RI BBON LOW
DI AMETER
0.50
PAUSE ON RI BBON
LOW
ENABLE
DI SABLE
SENSOR CALI BRATI ON
QUI CK CALI BRATI ON
MANUAL CALI BRATI ON
ADVANCED ENTRY
PAPER SENSOR
LEVEL
REFL PAPER LEVEL
GAP SENSOR LEVEL
MARK SENSOR
LEVEL
EMPTY SENSOR
LEVEL
TRAN SENSOR
GAI N
REFL SENSOR GAI N
PRI NTHEAD CLEANI NG
CLEAN HEAD SCHEDULE
CLEAN HEAD COUNTER
RESET COUNTER
CLEAN HEAD NOW
4 0
Defines t he print er response when THERMAL TRANSFER m ode is select ed and t he ribbon supply
begins t o dim inish.
Set s t he ribbon supply t hreshold diam et er ( 1.00 - 2.00 inches) t hat will t rigger a Low Ribbon
Warning prom pt , where:
I s t he default set t ing.
Allows t he print er t o ent er a paused condit ion when Ribbon Low Diam et er is m et , where:
Pauses when a Ribbon Low Diam et er condit ion is det ect ed; t he PAUSE Key m ust be pressed t o
proceed wit h t he print j ob.
No act ion is required by t he operat or; print ing can cont inue unt il a Ribbon Fault is declared.
( Default Set t ing)
Select s t he m edia sensor calibrat ion m et hod, where:
Set s t he values via int ernal print er calculat ions by feeding blank labels t hrough t he print er.
Manual calibrat ion t hat scans m edia and backing and out of st ock condit ion t o calculat e t he proper
calibrat ion.
Set s t he values via m anual ent ry ( t ypically for hard t o calibrat e label st ocks) , as described in t he
ADVANCED ENTRY CALI BRATI ON where:
Est ablishes t he t hreshold for t he paper value ( 0 - 255) , where 170 is t he default set t ing.
Est ablishes t he t hreshold for t he reflect ive value ( 0 - 255) , where 170 is t he default set t ing.
Est ablishes t he t hreshold for t he gap value ( 0 - 255) , where 040 is t he default set t ing.
Est ablishes t he t hreshold for t he m ark value ( 0 - 255) , where 040 is t he default set t ing.
Est ablishes t he t hreshold for t he em pt y value ( 0 - 255) , where 000 is t he default set t ing.
Est ablishes t he sensit ivit y of t he t ransm issive sensor ( 0 - 31) , where 15 is t he default set t ing.
Est ablishes t he sensit ivit y of t he reflect ive sensor ( 0 - 31) , where 15 is t he default set t ing.
Cont rols t he aut om at ic cleaning alert and funct ion, where:
Specifies t he inch ( or cent im et er) count at which t o clean t he print head, and if exceeded t hree
t im es, declare a Head Cleaning Fault . ( Not e t hat t he specified count [ 0 - 200 inches] will be
m ult iplied by one t housand, and t hat zero [ t he default set t ing] will disable t he funct ion.)
I ndicat es t he num ber of inches ( or cent im et ers) since a cleaning was last init iat ed.
Reset s t he Clean Head Count er t o zero t o rest art t he Clean Head Schedule.
I nit iat es t he cleaning process and reset s t he Clean Head Count er.
I TEM D ESCRI PTI ON