Datamax E-Class Mark III Professional Operator's Manual page 39

Hide thumbs Also See for E-Class Mark III Professional:
Table of Contents

Advertisement

Adva n ce d En t r y Ca libr a t ion ( con t in u e d)
St e p
Act ion
Raise t he cover assem bly t hen
proceed according t o t he m edia
t ype:
Die- cut – Rem ove a label or t wo
from t he liner t hen posit ion t he
liner in t he Media Sensor.
H
Not ched – Posit ion t he Media in
t he Media Sensor under t he not ch.
Reflect ive – Posit ion t he Media in
t he Media Sensor under t he black
m ark.
Lower and lat ch t he Cover
Assem bly.
Using t he
or
I
Gain Num ber t o 0.
Record t he reading as a TOF Value
for Gain Num ber 0 in t he t able.
Gain Number
Ch a pt e r 3 – Pr in t e r Ope r a t ion
D ispla ye d M e ssa ge
TRAN SENSOR GAI N
TRAN SENSOR GAI N
but t on, set t he
Sample Calibration Table
Label Value
00
252
01
250
02
248
...
...
31
09
( 1) Do not posit ion t he Media
Sensor under a perforat ion; and
if using preprint ed m edia, ensure
t he label area placed over t he
31
sensor is free of t ext , graphics,
09
lines, et c.
( 0 - 31)
( 2) Do not m ove t he Media
Sensor aft er t his st ep.
This is t he TOF Value for a gain
0
set t ing of 0, where " 248"
represent s t he current sensor
248
( 0 - 31)
reading.
TOF Value
248
Com m e n t
Difference Value
3 3