Adva n ce d En t r y Ca libr a t ion ( con t in u e d)
St e p
Act ion
Using t he
or
Gain Num ber det erm ined in t he
L
previous st ep. Press t he
t o enable t he set t ing.
Press t he
but t on again t o re-
ent er t he TRAN SENSOR GAI N ( or
REFL SENSOR GAI N, if using
reflect ive m edia) m enu it em .
Com plet e a t able ( see exam ple
below) using new m easurem ent s,
as follows:
( A) Raise t he Cover Assem bly.
Place t he label over t he Media
Sensor t hen lower and lat ch t he
Cover Assem bly. Record t he
sensor reading as " Paper" .
M
( B) Raise t he Cover Assem bly.
Place t he liner, not ch, or m ark
over t he Media Sensor t hen lower
and lat ch t he Cover Assem bly.
Record t he sensor reading as " Gap
( or Mark) " .
( C) Raise t he Cover Assem bly.
Rem ove all m edia from t he Media
Sensor t hen lower and lat ch t he
Cover Assem bly. Record t he
sensor reading as " Em pt y" .
Gain Number
Ch a pt e r 3 – Pr in t e r Ope r a t ion
D ispla ye d M e ssa ge
but t on, set t he
but t on
TRAN SENSOR GAI N
Paper
18
174
OK
18
yyy
( 0 - 31)
Selected Gain Table
Gap (or Mark)
42
Com m e n t
This exam ple uses Gain Num ber
18.
Where " yyy" is a num erical value
represent ing t he current sensor
reading.
The re- sam pled values m ay
differ from t hose previously
not ed. This is norm al; do not
readj ust t he Media Sensor.
Empty
9
3 5