D I SPLAYED I TEM
UNI TS OF MEASURE
I MPERI AL
METRI C
I NPUT MODE
DPL
LI NE
PL- Z
PL- I
PL- B
AUTO
USER LABEL MODE
ENABLED
DI SABLED
DPL EMULATI ON
STANDARD
ALLEGRO
PRODI GY PLUS
PRODI GY
4 6
Set s t he m easurem ent st andard used, where:
Uses inches. ( Default Set t ing)
Uses m illim et ers and cent im et ers.
Defines t he t ype of processing t hat will occur when dat a is received, where:
Processes dat a for st andard DPL print ing.
Processes dat a for Line Mode ( t em plat e) print ing.
Alt ernat ive program m ing language processing will be used, wit h t he except ion of t he following DPL
specific- param et ers: DPL Em ulat ion; SOP Em ulat ion; and Label St ore.
Processes dat a for PL- I print ing.
Processes dat a for PL- B print ing.
I dent ifies t hen act ivat es t he appropriat e em ulat ion parser for t he dat a.
Set s t he print er t o power- up as default , where:
Funct ions in st andalone m ode for quick access t o user defined form at s.
This m ode will rem ain act ive unt il disabled.
Funct ions in norm al m ode, await ing com m ands from a host . ( Default Set t ing)
Allows t he print er t o reproduce, for backward com pat ibilit y, label form at s wit h t he sam e
charact erist ics as t hose produced by legacy m odels, where:
St andard DPL processing will be used for print ing. ( Default Set t ing)
Processes DPL dat a as an Allegro® , including row posit ion calculat ions based on 194 dot s per inch
and t he except ions not ed below.
Processes DPL dat a as a Prodigy Plus® , including colum n calculat ions based on 200 dot s per inch
and t he except ions not ed below.
Processes DPL dat a as a Prodigy® , including colum n calculat ions based on 200 dot s per inch and t he
except ions not ed below.
Except ions:
Dat a Term inat or processing – When print ing I 2 of 5 bar codes D, J, and L, t he
first non- num eric charact er processed will t erm inat e t he bar code dat a field.
Bar Size except ion – When print ing I 2 of 5 bar code L, if t he bar size specified is
great er t han P ( 25) it is aut om at ically decreased t o 10.
Hum an Readable Font s fixed size – When print ing EAN and UPC bar codes B, C, F,
G, M, and N, a fixed font size is produced.
Line and box vert ical sizing anom aly – When print ing rot at ions 2 and 4, lines and
boxes are affect ed by t he vert ical m ult iplicat ion fact or defined in t he DPL Dxx
com m and.
Colum n posit ion default s – Colum n posit ions great er t han t he print head widt h are
adj ust ed back t o t he print able area t hen print ed.
Bar codes in rot at ion 3 - ( upside down / right t o left ) default sizing – When row
posit ion in rot at ion 3 is less t han bar code height , bar codes falling off t he label's
leading edge are pushed back ont o t he label.
< STX> L com m and – When no print able fields reside in t he form at , it result s in no
label m ovem ent .
I TEM D ESCRI PTI ON