ELECTRICAL REQUIREMENTS

NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical
fi xed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection
than what is displayed here. Always verify with your electrical service contractor that your circuit protection is
adequate and meets all applicable national and local codes. These numbers are provided in this manual simply for
reference and may change without notice at any given time.
TEMPSTAR Electrical Characteristics:
VOLTS
PHASE
208
1
208
1
230
1
230
1
208
3
208
3
230
3
230
3
380
3
380*
3
415
3
415
3
440
3
440
3
208
1
208
1
230
1
230
1
208
3
208
3
230
3
230
3
460
3
460
3
* This model is wired in a wye confi guration for the heaters.
07610-003-61-42-T
RINSE HEATER
HZ
RATINGS
50
12KW@240V
50
14KW@240V
50
12KW@240V
50
14KW@240V
50
12KW@240V
50
14KW@240V
50
12KW@240V
50
14KW@240V
50
12KW@380V
50
14KW@208V
50
12KW@415V
50
14KW@415V
50
12KW@460V
50
14KW@460V
60
12KW@240V
60
14KW@240V
60
12KW@240V
60
14KW@240V
60
12KW@240V
60
14KW@240V
60
12KW@240V
60
14KW@240V
60
12KW@480V
60
14KW@480V
TOTAL
TYPICAL
AMPS
ELECTRICAL CIRCUIT
71 A
78 A
100 AMP
78 A
100 AMP
86 A
110 AMP
45 A
49 A
48 A
53 A
29A
34A
26 A
29 A
21 A
25 A
69 A
76 A
100 AMP
76 A
84 A
110 AMP
43 A
47 A
46 A
51 A
22 A
25 A
SPECIFICATIONS
90 AMP
60 AMP
70 AMP
60 AMP
70 AMP
40 AMP
45 AMP
35 AMP
40 AMP
30 AMP
35 AMP
90 AMP
100AMP
60 AMP
60 AMP
60 AMP
70 AMP
30 AMP
35 AMP