Addendum; Jackson Technical Manual Addendum - Jackson TEMPSTAR Installation, Operation And Service Manual

Tempstar series upright door dishmachines
Table of Contents

Advertisement

Jackson Technical
Manual Addendum
Tempstar units that are manufactured with the above referenced data plate are able to be fi eld-
converted to different phases and voltages. To accomplish this, your unit should have shipped
with the Tempstar Phase Conversion Kit, part number 06401-003-71-71. This kit contains the
appropriate decals and schematics to apply to your unit once the conversion is complete.
All work should be performed only by Authorized Jackson Service Agents.
Steps:
1. Perform the appropriate wiring and component changes as necessary to achieve
the desired result. Reference Jackson technical manuals or contact technical service for
assistance.
2. Verify the Schematic is correct. If not, replace with the correct one from the kit.
3. At the power inlet, remove the "Wired For" decal and replace with the one that matches the
confi guration of your machine.
77
SERIAL NUMBER:
MODEL: Tempstar
40 F RISE BOOSTER
WASH MOTOR
WASH HEATER
4.1 KW 11.4 A
RINSE HEATER
TOTAL LOAD
70 F RISE BOOSTER
WASH MOTOR
WASH HEATER
4.1 KW 11.4 A
RINSE HEATER
10.5 KW 29.1 A 12.9 KW 32.4 A 12.9 KW 16.2 A
TOTAL LOAD
Intertek
4000897
Conforms to UL Std 921
Conforms to CSA
Std C22.2 No.168
40 F RISE BOOSTER
WASH MOTOR
WASH HEATER
4.1 KW 19.7 A
RINSE HEATER
TOTAL LOAD
70 F RISE BOOSTER
WASH MOTOR
WASH HEATER
4.1 KW 19.7 A
RINSE HEATER
10.5 KW 50.4 A 12.9 KW 56.1 A
TOTAL LOAD
Made in the USA
Jackson WWS, Inc.
P.O. Box 1060
Barbourville, KY. 40906
(606) 523-9795
09905-003-69-11D

ADDENDUM

208-230-460 Volt/60 Hz/3 Phase
208V
230V
3/4 HP
5.7 A
3/4 HP
5.7 A
3/4 HP
5 KW 12.6 A
5 KW
9 KW
25.0 A
11 KW 27.2 A
11 KW 13.8 A
42.1 A
45.5 A
21.9 A
208V
230V
3/4 HP
5.7 A
3/4 HP
5.7 A
3/4 HP
5 KW 12.6 A
5 KW
46.2 A
50.7 A
24.3 A
208-230 Volt/60 Hz/1 Phase
208V
230V
3/4 HP
5.7 A
3/4 HP
5.7 A
5 KW 21.7 A
9 KW
43.3 A
11 KW 47.8 A
68.7 A
75.2 A
208V
230V
3/4 HP
5.7 A
3/4 HP
5.7 A
5 KW 21.7 A
75.8 A
83.6 A
OPERATING PARAMETERS
MINIMUM WASH TEMPERATURE
150 F
MINIMUM RINSE TEMPERATURE
180 F
MINIMUM INCOMING WATER TEMPERATURE
70 F RISE BOOSTER
110 F
40 F RISE BOOSTER
140 F
WASH CYCLE TIME
45 SEC
RINSE CYCLE TIME
11 SEC
FLOW PRESSURE
10 PSI
07610-003-61-42-T
460V
1.8 A
6.3 A
460V
1.8 A
6.3 A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tempstar ltTempstar nbTempstar s

Table of Contents