Siemens SIMATIC S5 Manual page 258

Ip 266 positioning module
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

IP 266
Table 7-8. Overview of the Input Frame
Byte
0
Current mode
1
M function
2
Bit 7
Bit 6
0/1
0/1
Status bits for axis, controller and machine data
3
Current IP 266 error codes
Bytes 4 to 7 are used for actual position, distance to go or following error,
depending on the specified mode and on the current monitoring command.
4
Binary:
5
16-bit fixed-point number with sign (bit 7 in byte 4) used to forward the
integer positions of the value to the IP 266.
BCD:
Byte 4, bits 4 to 7: sign of the BCD number
Byte 4, bits 0 to 3 and
Byte 5, bits 0 to 7: 3 BCD digits
6
Binary:
7
16-bit binary number used to forward the decimal positions to the IP 266.
BCD:
Byte 6, bits 4 to 7: least-significant integer position
Byte 6, bits 0 to 3 and
Byte 7, bits 0 to 7: three decimal positions
EWA 4NEB 812 6057-02
Communication Between the CPU and the IP 266
Description
Bit 5
Bit 4
Bit 3
0/1
0/1
0/1
Recommen-
Bit 2
Bit 1
Bit 0
0/1
0/1
0/1
ded data
format
KF
KF
KM
KH
KF
KH
KF
KH