Chapter 4
Technical Specifications
Section 4.3

Copper Ethernet Port Specifications

The following details the specifications for copper Ethernet ports that can be ordered with the RS401.
c
Speed
10/100Base-TX
c
Auto-negotiating.
d
Shielded or unshielded.
e
Auto-crossover and auto-polarity.
f
RMS 1 minute.
Section 4.4

Fiber Optic Ethernet Port Specifications

The following sections detail fiber optic specifications for ports that can be equipped on the RUGGEDCOM RS401.
CONTENTS
Section 4.4.1, "10BaseFL Ethernet Optical Specifications"
Section 4.4.2, "Fast Ethernet (100 Mbps) Optical Specifications"
Section 4.4.1

10BaseFL Ethernet Optical Specifications

Mode
Connector
MM
ST
g
To convert from average to peak, add 3 dBm. To convert from peak to average, subtract 3 dBm.
h
Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when
determining maximum segment distances.
22
c
Connector
Duplex
RJ45
FDX/HDX
Cable Type
Tx λ (nm)
g
(um)
50/125
820
62.5/125
d
Cable Type
Wiring Standard
> CAT-5
TIA/EIA T568A/B
Tx Min
Tx Max
Sensitivity
(dBm
(dBm
(dBm
g
g
peak)
peak)
Average)
-19.8
-12.8
-16
-9
Maximum
e
Distance
100 m (328 ft)
Rx
Rx
Typical
Saturation
Distance
(dBm
(km)
g
g
Peak)
-34
-11.2
2
Copper Ethernet Port Specifications
RUGGEDCOM RS401
Installation Guide
f
Isolation
1.5 kV
Power
Budget
h
(dB)
18