Technical Specifications; Power Supply Specifications; Failsafe Alarm Relay Specifications - Siemens RUGGEDCOM RS401 Installation Manual

Hide thumbs Also See for RUGGEDCOM RS401:
Table of Contents

Advertisement

RUGGEDCOM RS401
Installation Guide

Technical Specifications

This section details the specifications and operating conditions of the device.
CONTENTS
Section 4.1, "Power Supply Specifications"
Section 4.2, "Failsafe Alarm Relay Specifications"
Section 4.3, "Copper Ethernet Port Specifications"
Section 4.4, "Fiber Optic Ethernet Port Specifications"
Section 4.5, "Serial Port Specifications"
Section 4.6, "Operating Environment"
Section 4.7, "Mechanical Specifications"
Section 4.1

Power Supply Specifications

Power Supply Type
12-24 VDC
48 VDC
b
HI (125/250 VDC)
b
HI (110/230 VAC)
a
(F) denotes fast-acting fuse; (T) denotes time-delay fuse.
b
This is the same power supply for both AC and DC.
Section 4.2

Failsafe Alarm Relay Specifications

Parameter
Max Switching Voltage
Rated Switching Current
Power Supply Specifications
Minimum Input
Maximum Input
10 VDC
36 VDC
88 VDC
85 VAC
Internal Fuse Rating
36 VDC
6.3 A(F)
59 VDC
2 A(T)
300 VDC
2 A(T)
265 VAC
Value
30 VAC, 80 VDC, 125 VAC, 250 VAC
0.3 A @ 30 VAC
1 A @ 30 VDC, 0.3 A @ 80 VDC
0.2 A @ 250 VAC
0.6 A @ 125 VAC
Technical Specifications
Maximum Power
Consumption
a
a
8 W
a b
Chapter 4
21

Advertisement

Table of Contents
loading