General Information
DTC faults are displayed by the controller.
Table 2-1. Possible DTC Faults
Fault
DTC Description
Check Engine
A fault not recognized by the
Fault
controller
Contact the engine manufacturer
for support.
Low Oil Pres-
Engine oil pressure has fallen
sure
below
pressure alarm level.
Underspeed
Engine speed has fallen below its
configured
level.
Overspeed
Engine speed has risen above its
configured overspeed alarm level.
Low Fuel Level
Engine's fuel level has fallen below
its configured low fuel level alarm.
Battery Under/
Engine's DC supply has fallen
Over Voltage
below or risen above its configured
alarm level.
To view the active alarms, repeatedly press the ↑ and ↓
buttons until the LCD window displays the alarm.
Continue to press the ↑ and ↓ buttons to cycle through
the alarms.
To exit the alarm screen, press the ↑ and ↓ buttons
simultaneously to enter the navigation menu. Once
entered, cycle to the desired operator screen.
The alarm condition must be corrected before a reset will
take place. If the alarm condition remains, it is not
possible to reset the unit. The exception to this is the Low
Oil Pressure alarm and similar 'active from safety on'
alarms, as the oil pressure is low with the engine at rest.
To clear alarms that stop the generator, refer to
Resetting the Maintenance
NOTE: The LCD backlight is on if the unit has sufficient
voltage while the unit is turned on, unless the unit is
cranking. In this case, the backlight is turned off.
If the controller is left in Stop mode for a period of
inactivity, the controller enters Power Save mode. To
'wake' the controller, press the Stop (O) button.
26
has
been
detected.
its
configured
low
oil
underspeed
alarm
Alarms.
Maintenance Screen
See
Figure
2-17. The Maintenance screen (
the maintenance alarms configured into the controller.
The three alarms are for servicing the fuel filter, oil filter,
and air filter.
Fuel Filter
Oil Filter
Air Filter
Figure 2-17. Maintenance Screen
Event Log Screen
See
Figure
2-18. The controller's event log (
a list of the last 15 recorded electrical trips or shutdown
events and the engine hours at which they occurred.
Once the log is full, any subsequent electrical trip or
shutdown alarm overwrites the oldest entry in the log.
The log always contains the most recent shutdown
alarms.
15/15
05 22PM 08/11/15
Digital input B
Restart
Figure 2-18. Event Log Screen
To view the event log:
1. Press the ↑ and ↓ buttons simultaneously to display
the navigation menu.
2. Cycle to the event log section and press the Auto
button to enter.
3. Repeatedly press the ↑ or ↓ buttons until the LCD
window displays the desired event.
Continuing to press down the ↑ or ↓ buttons will cycle
through past alarms. Eventually the most recent alarm
will display and the cycle begins again.
To exit the event log, press the ↑ and ↓ buttons
simultaneously to enter the navigation menu. Once
entered, cycle to the desired operator screen.

Owner's Manual for MLT6SMD Light Tower

) displays
7 HRS
7 HRS
7 HRS
02019
) displays
0 h 01 mins
01973