Operator Screens - Generac Power Systems MLT6SMD Owner's Manual

Light tower ligh
Table of Contents

Advertisement

Operator Screens

See
Figure
2-6. The operator screens display the most
relevant and critical information an operator will need to
correctly configure and use the unit. From these six
screens, the operator can access information necessary
to operate the unit under normal conditions.
Figure 2-6. Operator Screens Location
Home Screen
See
Figure
2-7. Default screen of the controller and
displays after the controller is powered up and the unit
management software is loaded. Displays the controller
mode, total operating hours, hours left until the next
service interval, engine operating status, and engine rpm.
If the unit is in Auto mode, the Home screen may also
display whether the scheduler or "dusk to dawn" are
enabled.
Figure 2-7. Home Screen
Owner's Manual for MLT6SMD Light Tower
Battery Voltage Screen
See
Figure
2-8. Displays the engine battery voltage. A
normal reading is 12–14V on 12 volt systems (with the
engine running).
Figure 2-8. Battery Voltage Screen
002354
Lights Screen
See
Figure
2-9. Enables the operator to turn the lights on
and off. Refer to
002544
General Information
Light Operation
for more information.
Figure 2-9. Lights Screen
002990