SPECIFICATIONS
3.1 TABLE OF SPECIFICATIONS (continued)
MOTOR: (60 Cycle Compressors)
24KT MODELS
Size:
40,50,60, 75HP
Type:
C---Flanged, Open Dripproof, 460V, A.C.,
Three Phase, 60 Cycles
40_C Maximum Ambient Temperature
Options Available: 200V, 230V and 575V
T.E.F.C. Also Available
Starter:
460V Full Voltage Magnetic
Options Available: 200V, 230V and 575V
Speed:
1770 RPM
3.2 LUBRICATION GUIDE---STANDARD COM-
PRESSORS (All 12 Series; 16 Series --- 60 and
75HP)
Sullair standard compressors are filled with SRF
1/4000 fluid factory fill.
Mixing of other lubricants within the compressor
unit will void all warranties!
SRF 1/4000 fluid should be changed every 4000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particle level, corrosive gases or strong oxidiz-
ing gases are present in the air.
For extended life synthetic lubricants contact the
nearest Sullair representative.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.
3.3 LUBRICATION GUIDE --- STANDARD COM-
PRESSORS (16 Series --- 100HP)
Sullair standard compressor are filled with Sullube
32 fluid as factory fill.
Mixing of other lubricants within the compressor
unit will void all warranties!
Sullube 32 fluid should be changed every 8000
hours or once a year, whichever comes first. The
fluid should be changed more frequently under se-
vere operating conditions, such as high ambient
temperatures coupled with high humidity, or when
high particulate level, corrosive gases or strong oxi-
dizing gases are present in the air.
14
WARNING
!
WARNING
!
STANDARD MODELS
40,50,60, 75 & 100 HP
C---Flanged, Open Dripproof, 460V, A.C.,
Three Phase, 60 Cycles
40_C Maximum Ambient Temperature
Options Available: 200V, 230V and 575V
T.E.F.C. Also Available
460V Full Voltage Magnetic
Options Available 200V, 230V and 575V
1770RPM and 3550RPM (100HP)
WARNING
!
"The Plastic Pipe Institute recommends against the
use of thermoplastic pipe to transport compressed
air or other compressed gases in exposed above
ground locations, e.g. in exposed plant piping." (I)
Sullube 32 should not be used with PVC piping sys-
tems. It may affect the bond at cemented joints. Cer-
tain other plastic materials may also be affected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.
3.4 LUBRICATION GUIDE---24KT COMPRES-
SORS
Sullair 24KT compressors are filled with a lubricant
which rarely needs to be changed. In the event a
change of fluid is required, use only Sullair 24KT
fluid.
WARNING
!
Mixing of other lubricants within the compressor
unit will void all warranties!
Sullair recommends that a 24KT sample be taken
at the first filter change and sent to the factory for
analysis. This is a free service. A sample kit with in-
structions and self---addressed container is to be
supplied by your Sullair Representative at start---
up. The user will receive an analysis report with rec-
ommendations.

APPLICATION GUIDE

Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This
could result in a fluid change interval differing from
that stated in the manual. Contact your Sullair deal-
er for details.