Daily Operation; Filter Maintenance; Separator Maintenance; General - Sullair LS-12 Operators Manual And Parts Lists

Industrial air compressor. 40, 50, 60, 75 & 100hp (30, 37, 45, 55 & 75kw) standard & 24 kt
Hide thumbs Also See for LS-12:
Table of Contents

Advertisement

Section 6
MAINTENANCE

6.1 GENERAL

As you proceed in reading this section, it will be easy
to see that the Maintenance Program for the air
compressor is quite minimal. The use of the service
indicators provided for the bearing filter, air filter and
fluid separator, will alert you when service mainte-
nance is required. When the maintenance gauge
shows red, maintenance for that specific item is re-
quir ed. S ee instr u c tions f or eac h item in
Parts Replacement and Adjustment

6.2 DAILY OPERATION

Prior to starting the compressor, it is necessary to
check the fluid level in the sump. Should the level be
low, simply add the necessary amount. If the addi-
tion of fluid becomes too frequent, a simple problem
has developed which is causing this excessive loss.
S ee the
Tr oubl eshooting S ec tion (6 . 8
sive Fluid Consumption for a probable cause and
remedy.
After a routine start has been made, observe the in-
strument panel gauges and be sure they monitor
the correct reading for their particular phase of op-
eration. After the compressor has warmed up, it is
recommended that a general check on the overall
compressor and instrument panel be made to as-
sure that the compressor is running properly.
DO NOT remove caps, plugs, and/or other compo-
nents when compressor is running or pressur-
ized.
Stop compressor and relieve all internal pressure
before doing so.
MAINTENANCE AFTER INITIAL 50
6.3
HOURS OF OPERATION
After the initial 50 hours of operation, a few mainte-
nance requirements are needed to clean the system
of any foreign materials. Perform the following main-
tenance operations to prevent unnecessary prob-
lems.
1. Clean the return line strainers.
2. Clean the return line orifices.
MAINTENANCE EVERY 4000
6.4
HOURS
After 4000 hours of operation, it will be necessary to
perform the following:
1. Clean the return line strainers.
2. Lubricate the Sullicon Control linkage.
3. Replace the fluid filter element and gasket.
4. STANDARD COMPRESSORS ONLY! Drain the
sump and change the compressor fluid.
22
S ec tion 6 . 7
Procedures.
) under Ex c es -
WARNING
!
Figure 6 ---1 Fluid Filter (P/N 250025 ---522)
,
* Repair Kit P/N 250025---526 (40---75HP)
Repair Kit P/N 250025---524 (100HP)

6.5 FILTER MAINTENANCE

Replace your fluid filter element and the gasket un-
der any of the following conditions, whichever oc-
curs first:
1. As indicated by the maintenance gauge.
2. Every 1000 hours.
3. Every 6 months.
4. STANDARD COMPRESSORS ONLY! Every
fluid change.

6.6 SEPARATOR MAINTENANCE

Replace the separator elements when your separa-
tor maintenance gauge shows red or after one (1)
year, whichever comes first. The separator ele-
ments must be replaced. DO NOT clean the separa-
tor elements.
6.7 PARTS REPLACEMENT AND ADJUSTMENT
PROCEDURES
FLUID FILTER ELEMENT REPLACEMENT
R e f e r t o F i g u r e
6 --- 1
1. Using a strap wrench, remove the old element
and gasket.
2. Clean gasket seating surface.
3. Apply a light film of fluid to the new gasket.
4. Hand---tighten new element until new gasket is
seated in the gasket groove. Avoid any nicks,
cuts or pinches to the gasket.
.