Lubrication Guide - Standard Compressors; Application Guide - Sullair TS-20 Operator's Manual And Parts List

Industrial air compressor, 100-250hp/75-187kw air-cooled & water-cooled standard & 24kt
Hide thumbs Also See for TS-20:
Table of Contents

Advertisement

Section 3
SPECIFICATIONS
MOTOR: (60 Hz Compressors)
Size:
Type:
Starter:
3.2 LUBRICATION GUIDE-STANDARD COMPRES-
SORS
Sullair TS-20 compressors are filled with Sullube.
Mixing of other fluids within the compressor will
void all warranties.
Sullube fluid should be changed every 8000 hours
or once a year, whichever occurs first. The fluid
should be changed more frequently under severe
operating conditions, such as high ambient temper-
atures coupled with high humidity, high particulate
level, corrosive or strong oxidizing gases are pres-
ent in the air.
Maintenance of all other components is still recom-
mended as indicated in the Operator's Manual.

3.3 APPLICATION GUIDE

Sullair encourages the user to participate in a fluid
16
STANDARD MODELS
100 - 250 HP/75 - 187KW
Open Dripproof, 460V, A.C., Three Phase,
60 Cycles
105ºF (41ºC) Maximum Ambient Temperature,
TEFC also Available
460V Full Voltage Magnetic
Options Available: 200 to 230 and 575V
analysis program with the fluid suppliers. This could
result in a fluid change interval differing from that
stated in the manual.
For more information on a fluid analysis program,
contact your local Sullair representative or the
Sullair Factory Service Department.
"The Plastic Pipe Institute recommends against
the use of thermoplastic pipe to transport com-
pressed air or other compressed gases in
exposed above ground locations, e.g. in
exposed plant piping." (I)
PVC piping should not be used with Sullube sys-
tems. It may affect the bond at cemented joints.
Certain other plastic materials may also be
affected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.