Remote Commands
pr_kbq
qbjm
qokqfjb=
sbo
sca_oq=
106
Query Response: SELMODE -m (mode) --min 0 -- max 1
Description: Set subnet mask to be used when DHCP is OFF
Command Format: SUBNET -s (static addr)
Command Params: -s static address formatted xxx.xxx.xxx.xxx
Query Format: SUBNET -?
Query Response: SUBNET -a(active addr) -s(static addr)
Response Params: -a(active addr): returns active address
Description: Query only command for the temperature of the unit.
Query Format: TEMP -?
Query Response: TEMP -c (celsius) -f (fahrenheit)
Description: Set transition time
Command Format: TRNTIME -s (seconds)
Parameters: -s (seconds): 1.5 - 5.0 (default: 1.5)
Query Format: TRNTIME -?
Query Response: TRNTIME -s (seconds) --min 1.5 -- max 5
Description: Display Version info
Command Format: VER
Parameters: N/A
Query Format: N/A
Query Response: N/A
Description: Set VFD brightness
Command Format: VFDBRT -b (brightness) -f
Parameters:
-b (brightness): 1 - 16 (default: 10)
-f: Command from front panel
Query Format: VFDBRT -?
Query Response: VFDBRT -b (brightness) --min 1 -- max 16