Figure 2-24-3
Note:
If the cleaner Base Plate is removed, execute the
Cleaner roller Position adjustment.
2-24-2. Cleaner Roller Position
Adjustment
<Tools required>
Eccentric Driver (VFK0357)
1.
Observe the clearance (A) between Cleaner
Roller and cylinder Unit as shown in Figure
2-24-4. And make sure that it is within 1.0 to
1.2mm.
2.
If not, loosen the 2 screws (B) as shown in figure
2-24-2 and adjust the position of Cleaner Base
Plate by moving arrow direction (A ←→ A) using
the Eccentric driver so that the clearance (A) is
within the specification. And tighten the 2 screws
(B).
Figure 2-24-4
2-25. Distinction SW Unit
Replacement
(Studio VTR only)
(Removal)
1.
Disconnect the connector (A) on the P.C.Board
(A). (Please refer item "7
2.
. Table of Connector" about reference number of
connector and name of P.C.Board.)
Click this mark
Connector".
2.
Remove the MIC Drive Rev Spring at Distinction
Switch Unit side as shown in Figure 2-25.
3.
Unscrew the 3 screws (A) and remove the MIC
Rail Unit as shown in Figure 2-25.
(Installation)
1.
Install the new Distinction Switch Unit following
the removal steps in reverse order.
2.
Confirm that the M and L cassettes touch to
Distinction Switch Unit correctly.
MECH-53
, then go to item "7. Table of
(A)
DISTINCTION
SW UNIT
Figure 2-25