[CC96] Lever path HP abnormality
* If [EAF5] occurs two times consecutively, it becomes a [CC96] error.
Classification
Finisher related service call
Check item
Lever path home position
sensor
Lever path motor
Finisher control PC board
Parts to be replaced
Lever path home position
sensor
Lever path motor
Finisher control PC board
[CDE0] Paddle HP abnormality
* If [ED15] occurs two times consecutively, it becomes a [CDE0] error.
Classification
Finisher related service call
Check item
Paddle home position sensor
Paddle motor
Finisher control PC board
Parts to be replaced
Paddle home position sensor
Paddle motor
Finisher control PC board
[EAF2] Stapler motor HP abnormality
Classification
Finisher related service call
e-STUDIO477S/527S/477SL
ERROR CODE AND TROUBLESHOOTING
Error content

Lever path HP abnormality

Measures
Sensor check (S15)
Connector check (P7-4)
Harness check
Motor check (M10)
Connector check (P18-1)
Harness check
Board check
Connector check (J7, J18)
Harness check
Remark
Error content

Paddle HP abnormality

Measures
Sensor check (S3)
Connector check (P8-4)
Harness check
Motor check (M3)
Connector check (P5-4)
Harness check
Board check
Connector check (J5, J8)
Harness check
Remark
Error content
Stapler motor HP abnormality