6.50.02 SYS Commands

Major
Sub-
Command
Command
System Commands
SYS
OPN/OPEN
SYS
CLS/CLOSE
SYS
ADR/
Property of Ramsey Electronics, Inc.
ADDRESS
Do not reproduce or distribute.
SYS
ECH/ECHO
SYS
TIMEOUT
SYS
HELP
SYS
PASSWORD AAAAAAAA
SYS
SECURE
SYS
PAUSE
SYS
PROMPT
Format
Low
###
0
###.###
0.0
ON/OFF
ON
#
0
AAA
AAAAAAAA
A
ON/OFF
ON
###
ON/OFF
ON
86
High
Returns
999
OK/BAD
OK/BAD
999.999
OK/BAD
OFF
OK/BAD
7200
OK/BAD
List of
commands
Confirnation,
OK/BAD
OFF
Confirmatio
n,OK/BAD
OK/BAD
OFF
OK/BAD
Description
Opens serial
communications with
this COM3010 if
address matches
setting.
Closes serial
communication. After
this, nothing is sent or
received.
Once open, this
changes to a new
address, and leaves
session open. First
address must match old
address, second
address must be within
0->999
If echo is on, COM3010
sends back everything it
receives through the
RS232 port.
Sets serial comm
timeout from 1 to 30
minutes. 0 = No
timeout, time in
seconds
Lists commands with
associated Major
Command.
Changes the password
to that specified
Secure Enables and
Disables the password.
Pauses serial interpreter
for specified 10's of
milliseconds.
Turns the command
prompt on and off.
Default ON