Master And Device Firmware Kit Files For Massio Controlpads; Required Order Of Firmware Updates; Required Order Of Firmware Updates For Dvx Controllers; Upgrading Firmware Via Usb - AMX NX-1200 Webconsole And Programming Manual

Nx-series controllers, enova dvx all-in-one presentation / digital media switchers, massio controlpads
Table of Contents

Advertisement

Master and Device Firmware Kit Files for Massio ControlPads

Below is a table outlining the Master and Device Firmware (*.kit) files used by Massio ControlPads:
Master and Device Firmware Files for Massio ControlPads
MCP-106/108
NOTE: The HTTP f irmware kit enables you to upgrade f irmware via an HTTP server. Upgrading a Massio ControlPad to f irmware
version 1.4 or higher requires the current f irmware version on the ControlPad to be version 1.3.106 or higher. Follow the same steps
in NetLinx Studio as you would with a typical f irmware upgrade. Upgrading f irmware via HTTP server is typically much faster than
upgrading with the standard f irmware kit f iles. See the Upgrading Firmware via NetLinx Studio section on page 31 for more
information.

Required Order of Firmware Updates

The Upgrading Firmware via NetLinx Studio instructions (below) apply equally to all types of firmware files. However, it is important
that the firmware files are upgraded in the following order:
1.
First, upgrade the Master firmware.
2.
When that process is complete, upgrade the Device firmware.
IMPORTANT: ALWAYS consult the Readme.TXT f ile bundled with the f irmware f ile for any special instructions before upgrading to a
newer f irmware version. If no specif ics are provided, use the order provided above.

Required Order of Firmware Updates for DVX Controllers

Upgrade firmware in the following order:
1.
First, upgrade the A/V Switcher/Scaler firmware.
2.
When that process is complete, upgrade the Master firmware.
3.
When that process is complete, upgrade the Device firmware.
IMPORTANT: ALWAYS consult the Readme.TXT f ile bundled with the f irmware f ile for any special instructions before upgrading to a
newer f irmware version. If no specif ics are provided, use the order provided above.

Upgrading Firmware via USB

All X-Series controllers support firmware upgrades via a USB solid-state drive. You can upgrade via USB by selecting the
appropriate .kit file and initiating the upgrade via telnet. The "IMPORT KIT" telnet command causes the controller to search the
attached USB drive for all valid .kit files and display the files as a list. From here you can select the .kit file to use and initiate the
firmware upgrade. See the IMPORT KIT section on page 107 for more information.

Upgrading Firmware via NetLinx Studio

NOTE: These steps assume that you have already established a connection with the target Central Controller (IP connection is
preferred.) See the Initial Conf iguration section on page 19 for details.
1.
In NetLinx Studio. click on the OnLine Tree tab (in the Workspace Bar) to view the devices on the System.
2.
In the OnLine Tree tab, click Display and select Refresh System from the context menu. Doing so establishes a new connection
to the System and populates the device tree with devices on that system.
3.
After the Communication Verif ication dialog indicates active communication between the PC and the Central Controller, verify
the Master and associated devices (including the Device Controller) are listed in the OnLine Tree.
4.
In NetLinx Studio, select Tools > Firmware Transfers > Send to NetLinx Device (FIG. 24):
NetLinx Studio - Tools > Firmware Transfers > Send to NetLinx Device
FIG. 24
This step opens the Send to NetLinx Device dialog.
NX-Series Controllers - WebConsole & Programming Guide
Master Firmware: SW2102_MCP_10x_vx_x_xxx.kit
Device Firmware: SW2102_MCP_10x_Device_vx_xx_x.kit
HTTP Firmware Kit: SW2102_MCP_10x_vx_x_xxx-http.kit