Audit Logs

An audit log includes the date/time of the event, the event type, the software or hardware component where the event occurred,
the source of the event, the subject identity, and the outcome of the event. For events related to a remote device, the audit log
includes the source and destination network addresses and ports or protocol identifiers.
The Master generates an audit record for the following events:
Each successful or unsuccessful attempt to access security files

Alerts and errors

Starting/Shutting down audit logging

Any blocking (including the reason) of access based on a UID, terminal, or access port

Any configuration change. The record includes the source and destination network addresses and ports or protocol

identifiers.
Denial of access due to excessive login attempts

Each log off

Each successful or unsuccessful attempt to log on to the application

Successfully or unsuccessfully loading and starting a Duet module

Modification of permissions associated with roles

Connection and loss of connection to an NTP server. (Loss of connection is defined as three successive failed polls. A single

successful poll constitutes a re-connection.
System reboot

Software or firmware updates

Creation, modification, and deletion of user accounts

NOTE: The Master retains audit log records for 30 days (or less depending on available space), after which they are automatically
purged.

Banners

Banners enable you to display pre- and post-login text in the WebConsole and terminal interfaces. Banner files are text files
containing up to 500 characters in each file. (Any additional characters are discarded.)
NOTE: Banner f iles are user-provided and optional. If no f iles are found, no banner appears.
The following special characters are allowed for use in banner text messages:
! " # $ % & ' ( ) * + , - . / : ; < = > ? @ [ \ ] ^ _ ` { | } ~
Also allowed are any printable ASCII characters (including "space"): A-Z, a-z, 0-9.
Pre-login banners must be named "banner.txt" and stored in the /user directory on the Master. Post-login banners are obtained
from one or more files in the /user directory. Post-login banner text is a concatenation of the allroles_banner.txt file, followed by all
of the applicable <role>_banner.txt files, where <role> is the name of a defined Role in the system. The applicable files are those
that match the Roles assigned to the user that logged in. If a Role is currently locked, its banner file is not included.
NOTE: If you load a new "banner.txt" f ile with new content to the Master, you must reboot the Master to display the new f ile.