System Auto-Setup check box – select to place the system in auto-setup mode (i.e., the mode wherein the system requires only a
A
single IP address for the integrated Master, and each endpoint is automatically configured for communication via a private LAN
hosted by the integrated Master).
The following must be adhered to when using auto-setup mode (default):
 
Endpoints must be set to DHCP Mode (default)
 
Endpoints must use NDP Master connection mode (default)
 
Endpoints must not be currently bound (traditional NetLinx binding) to a Master
 
Endpoints DIP switch setting for Toggle #3 (network connectivity) is ignored while in auto-setup mode
NOTE: Some devices run on a secured f ile-system. As such, f ile-system operations (e.g., Load and Save operations) may not be
supported by the device's default capabilities and may require downloading a f ile manager application.
Alarms – if any are red, consult the individual Fan, Power, and Temperature components on the page to help pinpoint the location of
the problem.
Refresh button – if necessary, use the Refresh button to view system status changes.
Chassis f ield – this field contains readouts for individual fan speeds, individual power supply status, and the current temperature of
B
the chassis (shown in degrees Celsius). Each readout displays in a color to convey statuses of OK, Fail, or no problems detected
(black). Fan speed information is displayed by individual fans (Fan #) and the fan assembly where each fan is located (FAN ASM #).
Power supply and temperature information is available in each switcher's General Specifications table in the "Product Overview and
General Specifications" chapter.
Master CPU (MCPU) Board f ield – this field displays information for Status, Model number of the integrated Master, FG (part)
C
number, Version, Temperature (actual degrees in Celsius with OK or FAIL status), and Power (OK or FAIL status).
Input and Output Board f ields – these fields give detailed information for each input or output board in the enclosure: Slot, Status,
D
Type, FG (part) number, Version, Temperature (actual degrees in Celsius with OK or FAIL status), and Power (OK or FAIL status). A
red Reboot button at the right cycles power to the individual board.
Input and Output Audio Expansion Boards f ields – these fields give detailed information for each expansion input or output board
E
in the enclosure: Slot, Status, Type, FG (part) number, Version, Temperature (actual degrees in Celsius with OK or FAIL status), and
Power (OK or FAIL status). A red Reboot button at the right cycles power to the individual board.
Switcher Setup (Save, Load, and Group Restore to Default) buttons – after a system has been set up per the installation's
F
requirements, the configuration can be saved and reloaded onto another system(s) or backup system(s) for reuse. The Group
Restore to Default button returns the system to its last previously saved state. This button will restore control values to default
(initial) values. (This Restore button performs the same function for the entire system as the Configuration page's Restore to
Default button does for individual inputs or outputs.)
Refresh button – if necessary, use the Refresh button to view system status changes.
G
System Conf iguration Interface Tips
To change the network connection type from DHCP (default) to Static IP – navigate to Network/IPv4; click on Specific IP

Address; enter values into the IP Address, Subnet Mask, and Gateway fields; then click Accept.
To enable/disable auto-setup ¡V navigate to Switcher/Status; click the System Auto-Setup check box to add a check mark

(enabled) or remove a check mark (disabled).
To route audio without the benefit of audio options available via the interface – navigate to Switcher/Configuration; select

Audio Switch Mode; select Outputs Only in the Config Viewer options; select the desired output; select Switched Audio
Routing from the General options.