Fit the replacement bulb and replaced
the protective cover, screwing it firmly
into place.
The catalytic liners (if fitted) are heavily
soiled and difficult to clean.
To ensure that the stay-clean linings
operate effectively, the oven should be
heated to at least 200°C whenever heavy
soiling has occurred during roasting or
grilling. If this is not done, the soiling
burns onto the linings and they become
black and shiny. In this case new liners
must be purchased from your
Rangemaster dealer. For after sales
service see the 'Customer Care' leaflet.

Installation

Warning: This appliance must be
correctly installed by a suitably
qualified person strictly in accordance
with the manufacturer's instructions.
The manufacturers decline
responsibility for injury or damage to
person or property as a result of
improper installation of this
appliance.
This appliance conforms to DC No 13/4/
89 and the standards of CEE DTD 87/
308 of 2/6/1987 regarding the
elimination of radio interference.
USERS GUIDE
Electrical connection
Electrical Installation must comply with
all relevant local and national regulation.
Make sure that the voltage supply is the
same as the rating given on the data
plate positioned on the lower part of the
front of the oven. This appliance must be
connection to an A.C. single phase 230
V, 50 Hz electricity supply. The total
rated load is 2,95 kW. The oven must be
connected to a 16 amp power supply via
a suitable isolator with an on-off switch,
and protected by a 16 amp fuse. The
isolator should be easily accessible in
case of maintenance or emergency. A
suitable cable, which complies with all
local and national regulations, must be
used. This should be of type H05 RR-F,
3- core, and with a minimum sectional
area of 1,5 mm.
The connection clamp for the cable is at
the rear of the appliance. Unscrew and
remove the cover then insert the cable by
way of the cable clip and connect.
Warning: This appliance must be
earthed.
The earth conductor of the mains cable
must be longer than the other two
conductors; in order that the it would
become disconnected last should the
cable be pulled or work loose following
installation. Secure the cable by
tightening the cable clip screws fully,
then replace and secure the cover.