OPERATING CAPACITY (ES-2000's) (RACKS/HOUR)
RACKS PER HOUR
RACKS PER HOUR (OPTION)
DISHES PER HOUR
GLASSES PER HOUR
OPERATING CAPACITY (ES-2000HH) (RACKS/HOUR)
RACKS PER HOUR
DISHES PER HOUR
GLASSES PER HOUR
OPERATING CAPACITY (ES-2000HHV) (RACKS/HOUR)
RACK PER HOUR
DISHES PER HOUR
GLASSES PER HOUR
OPERATING CAPACITY (ES-2000-V) (RACKS/HOUR)
RACK PER HOUR
DISHES PER HOUR
GLASSES PER HOUR
OPERATING CYCLE (ES-2000's) (SECONDS)
WASH TIME
RINSE TIME
TOTAL CYCLE TIME
TOTAL CYCLE TIME (OPTION)
OPERATING CYCLE (ES-2000HH) (SECONDS)
WASH TIME
RINSE TIME
TOTAL CYCLE TIME
OPERATING CYCLE (ES-2000HHV) (SECONDS)
WASH TIME
RINSE TIME
TOTAL CYCLE TIME
* Total time extended by 30 seconds.
OPERATING CYCLE (ES-2000-V) (SECONDS)
WASH TIME
RINSE TIME
TOTAL CYCLE TIME
*Total time extended by 30 seconds.
TUB CAPACITY (GALLONS)
WASH TUB (MINIMUM) (ES-2000's)
WASH TUB (MINIMUM) (ES-2000-CS)
SECTION 1: SPECIFICATION INFORMATION
ES-2000 SERIES SPECIFICATIONS
40
48
1000
1000
40
1000
1000
30
750
750
30
750
750
40
15
90
72
44
25
90
44
25
120
40
15
120
1.7
1.2
ES-2000 & ES-4000 Series Installation/Operation Manual 7610-011-35-10
Issued: 10-29-2007 Revised: N/A
WASH PUMP CAPACITY
GALLONS PER MINUTE
TEMPERATURES
WASH---°F (MINIMUM)
WASH---°F (MINIMUM) (ES-2000HH/HHV ONLY)
WASH---°F (RECOMMENDED)
RINSE---°F (MINIMUM)
RINSE---°F (MINIMUM) (ES-2000HH/HHV ONLY)
RINSE---°F (RECOMMENDED)
ELECTRICAL REQUIREMENTS
WASH PUMP MOTOR HORSEPOWER
NOTE: Typical Electrical Circuit is based upon (1) 125% of
the full amperage load of the machine and (2) typical
fixed-trip circuit breaker sizes as listed in the NEC 2002
Edition. Local codes may require more stringent protec-
tion than what is displayed here. Always verify with your
electrical service contractor that your circuit protection is
adequate and meets all applicable national and local
codes. These numbers are provided in this manual sim-
ply for reference and may change without notice at any
given time.
VOLTS
HERTZ
ES-2000's
115
60
WATER REQUIREMENTS
INLET TEMPERATURE (MINIMUM)
INLET TEMPERATURE (RECOMMENDED)
INLET TEMPERATURE
ES-2000HH MODELS (RECOMMENDED)
GALLONS PER HOUR
WATER LINE SIZE NPT (MINIMUM)
DRAIN LINE SIZE NPT (MINIMUM)
FLOW PRESSURE P.S.I.
MINIMUM CHLORINE REQUIRED (PPM)
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided
on this page is for reference only and may be subject to
change without notice.
2
61
120
130
140
120
130
140
3/4
TYPICAL
TOTAL
ELECTRICAL
PHASE AMPS
CIRCUIT
1
12.0
15 AMP
120°F
140°F
130°F
68
3/4"
2"
20 ±5
50