Cisco MDS 9216 Configuration Manual page 93

Mds 9000 series san volume controller
Hide thumbs Also See for MDS 9216:
Table of Contents

Advertisement

Chapter 10
Configuring a Dual Fabric SAN Environment
switch1(config-ivr-zone)# member pwwn 23:31:00:05:30:00:8d:e2 vsan 12
switch1(config-ivr-zone)# member pwwn 20:06:00:a0:b8:0f:6c:34 vsan 2
switch1(config-ivr-zone)# exit
Set up the IVR zone to allow SVC management on both switches to talk to each other.
Step 12
switch1(config)# ivr zone name ivr_4_14
switch1(config-ivr-zone)# member pwwn 27:90:00:05:30:00:33:2a vsan 4
switch1(config-ivr-zone)# member pwwn 27:8f:00:05:30:00:33:2a vsan 4
switch1(config-ivr-zone)# member pwwn 23:34:00:05:30:00:8d:e2 vsan 14
switch1(config-ivr-zone)# member pwwn 23:35:00:05:30:00:8d:e2 vsan 14
switch1(config-ivr-zone)# exit
Create the IVR zone set with the IVR zones and activate the IVR zone set.
Step 13
switch1(config)# ivr zoneset name ivr_zs
switch1(config-ivr-zoneset)# member ivr_2_12
switch1(config-ivr-zoneset)# member ivr_12_2
switch1(config-ivr-zoneset)# member ivr_4_14
switch1(config-ivr-zoneset)# exit
switch1(config)# ivr zoneset activate name ivr_zs
Zone set activation is now initiated. Check inter-VSAN zoneset status.
If any VSANs are configured to permit the default-zone, then you must use the force option to activate
the IVR zone set
switch1(config)# ivr zoneset activate name ivr_zs force
Zone set activation is now initiated. Check inter-VSAM zoneset status.
Bring up all interfaces, including the E-port, for the IVR transit VSAN.
Step 14
switch1(config)# interface fc8/2, fc8/3
switch1(config-if)# no shutdown
switch1(config-if)# exit
switch1(config)# interface fc8/17
switch1(config-if)# switchport trunk mode on
switch1(config-if)# switchport mode E
switch1(config-if)# no shutdown
switch1(config-if)# switchport trunk allowed vsan 20
switch1(config-if)# exit
You have now configured the first fabric for the dual fabric SAN environment displayed in
To configure a dual fabric SAN environments in the second fabric, follow these steps:
Step 1
Get the switch WWN information for both switches (see Step 1 in the previous procedure).
Create the VSANs in Switch2.
Step 2
switch2# configure terminal
switch2(config)# vsan database
switch2(config-vsan-db)# vsan 12
switch2(config-vsan-db)# vsan 12 interface fc7/2
switch2(config-vsan-db)# vsan 13
switch2(config-vsan-db)# vsan 13 interface fc7/3
switch2(config-vsan-db)# vsan 14
switch2(config-vsan-db)# vsan 20
switch2(config-vsan-db)# exit
Set the static domains in Switch 2.
Step 3
switch2(config)# fcdomain domain 12 static vsan 12
78-16119-01, Cisco MDS SAN-OS Release 1.3
Cisco MDS 9000 Family SAN Volume Controller Configuration Guide
Sample Configuration
<-- target port
<-- initiator port
Figure
10-1.
10-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 9500 series

Table of Contents