Cisco MDS 9216 Configuration Manual page 91

Mds 9000 series san volume controller
Hide thumbs Also See for MDS 9216:
Table of Contents

Advertisement

Chapter 10
Configuring a Dual Fabric SAN Environment
Figure 10-1 Traffic Isolation and Connectivity Using SVC and IVR
Initiator
Management
Target
To configure a dual fabric SAN environment in the first fabric, follow these steps:
Get the switch WWN information for both switches.
Step 1
switch1# show wwn switch
Switch WWN is 20:00:00:05:30:00:41:de
switch2# show wwn switch
Switch WWN is 20:00:00:05:30:00:07:1e
Step 2
Create the VSANs in Switch1.
switch1# configure terminal
switch1(config)# vsan database
switch1(config-vsan-db)# vsan 2
switch1(config-vsan-db)# vsan 2 interface fc8/2
switch1(config-vsan-db)# vsan 3
switch1(config-vsan-db)# vsan 3 interface fc8/3
switch1(config-vsan-db)# vsan 4
switch1(config-vsan-db)# vsan 20
switch1(config-vsan-db)# exit
switch1(config)#
Step 3
Set the static domains in Switch 1.
Sw1(config)# fcdomain domain 2 static vsan 2
Sw1(config)# fcdomain domain 3 static vsan 3
Sw1(config)# fcdomain domain 4 static vsan 4
Sw1(config)# fcdomain domain 20 static vsan 20
Configure the SVC interface into the correct VSANs in Switch 1.
Step 4
switch1(config)# int svc 1/1 - 2
switch1(config-if)# no initiator vsan 1
switch1(config-if)# initiator vsan 2
switch1(config-if)# no target vsan 1
switch1(config-if)# target vsan 3
switch1(config-if)# no mgmt vsan 1
switch1(config-if)# mgmt vsan 4
switch1(config-if)# exit
78-16119-01, Cisco MDS SAN-OS Release 1.3
fc8/3
VSAN 3
fc8/17
VSAN 4
Switch
VSAN 2
fc8/2
Cisco MDS 9000 Family SAN Volume Controller Configuration Guide
Host 1
fc7/3
Transit
fc7/17
VSAN 20
fc7/2
IBM controller
<-- target port
<-- initiator port
Sample Configuration
Initiator
VSAN 13
Management
VSAN 14
Switch
Target
VSAN 12
10-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 9500 series

Table of Contents