Cisco MDS 9216 Configuration Manual page 92

Mds 9000 series san volume controller
Hide thumbs Also See for MDS 9216:
Table of Contents

Advertisement

Sample Configuration
Set the default zone configuration for the transit VSAN in Switch 1.
Step 5
switch1(config)# no zone default-zone permit vsan 20
Step 6
Configure the target and SVC initiators in a zone in Switch 1.
switch1(config)# zone name z_2 vsan 2
switch1(config-zone)# member pwwn 20:06:00:a0:b8:0f:6c:34
switch1(config-zone)# member pwwn 27:8d:00:05:30:00:33:2a
switch1(config-zone)# member pwwn 27:89:00:05:30:00:33:2a
switch1(config-zone)# exit
switch1(config)# zoneset name zs_2 vsan 2
switch1(config-zoneset)# member z_2
switch1(config-zoneset)# exit
switch1(config)# zoneset activate name zs_2 vsan 2
Zone set activation is now initiated. Check zone status.
Configure the initiator and SVC targets in a zone in Switch 1.
Step 7
switch1(config)# zone name z_3 vsan 3
switch1(config-zone)# member pwwn 21:01:00:e0:8b:29:f0:04
switch1(config-zone)# member pwwn 27:8e:00:05:30:00:33:2a
switch1(config-zone)# member pwwn 27:8a:00:05:30:00:33:2a
switch1(config-zone)# exit
switch1(config)# zoneset name zs_3 vsan 3
switch1(config-zoneset)# member z_3
switch1(config-zoneset)# exit
switch1(config)# zoneset activate name zs_3 vsan 3
Zone set activation is now initiated. Check zone status.
Configure the SVC management N ports in a zone in Switch 1.
Step 8
switch1(config)# zone name z_4 vsan 4
switch1(config-zone)# member pwwn 27:90:00:05:30:00:33:2a
switch1(config-zone)# member pwwn 27:8f:00:05:30:00:33:2a
switch1(config-zone)# exit
switch1(config)# zoneset name zs_4 vsan 4
switch1(config-zoneset)# member z_4
switch1(config-zoneset)# exit
switch1(config)# zoneset activate name zs_4 vsan 4
Zone set activation is now initiated. Check zone status.
Enable and configure IVR using the switch WWNs (see Step 1 for the required WWNs).
Step 9
switch1(config)# ivr enable
switch1(config)# ivr vsan-topology database
switch1(config-ivr-topology-db)# autonomous-fabric-id 1 switch-wwn 20:00:00:05:30:00:41:de
vsan-ranges 2,4,20
switch1(config-ivr-topology-db)# autonomous-fabric-id 1 switch-wwn 20:00:00:05:30:00:07:1e
vsan-ranges 12,14,20
switch1(config-ivr-topology-db)# exit
switch1(config)# ivr vsan-topology activate
Set up the IVR zone to allow SVC initiators in Switch 1 to talk to the target port in Switch 2.
Step 10
switch1(config)# ivr zone name ivr_2_12
switch1(config-ivr-zone)# member pwwn 27:8d:00:05:30:00:33:2a vsan 2
switch1(config-ivr-zone)# member pwwn 27:89:00:05:30:00:33:2a vsan 2
switch1(config-ivr-zone)# member pwwn 20:07:00:a0:b8:0f:6c:34 vsan 12
switch1(config-ivr-zone)# exit
Step 11
Set up the IVR zone to allow SVC initiators in Switch 2 to talk to target port in Switch 1.
switch1(config)# ivr zone name ivr_12_2
switch1(config-ivr-zone)# member pwwn 23:30:00:05:30:00:8d:e2 vsan 12
Cisco MDS 9000 Family SAN Volume Controller Configuration Guide
10-4
Chapter 10
Configuring a Dual Fabric SAN Environment
<-- target
<-- svc initiator
<-- svc initiator
<-- initiator
<-- svc target
<-- svc target
<-- svc mgmt
<-- svc mgmt
78-16119-01, Cisco MDS SAN-OS Release 1.3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mds 9500 series

Table of Contents