Standards Relevant To The Emc Directive - Mitsubishi Electric QS001CPU User Manual

Qscpu series safety programmable controller melsec-qs series
Table of Contents

Advertisement

9
EMC, LOW VOLTAGE, AND MACHINERY DIRECTIVES

9.1.1 Standards relevant to the EMC Directive

(1) Emission related standards
Standard
Test item
CISPR16-2-3
Radiated emission
EN61131-2:
2007
CISPR16-2-1,
CISPR16-1-2
Conducted emission
(2) Immunity related standards
Standard
Test item
EN61000-4-2
Electrostatic discharge
*1
immunity
EN61000-4-3
Radiated, radio-frequency,
electromagnetic field
*1
immunity
EN61000-4-4
Fast transient burst
*1
immunity
EN61131-2:
EN61000-4-5
2007
Surge immunity
EN61000-4-6
Conducted RF immunity
EN61000-4-8
Power-frequency magnetic
field immunity
EN61000-4-11
Voltage dips and interruption
immunity
Table9.1 Emission related standards
Test description
The electromagnetic wave which
the product emits to the external
*2
space is measured.
The noise level which the product
emits to the power line is
*2
measured.
* 1 : QP: Quasi-Peak value, Mean: Average value
* 2 : Programmable controller is an open type device (a device designed to be housed in other
equipment) and must be installed inside a conductive control panel. The tests were conducted
with the programmable controller installed in a control panel, applying the maximum applicable
input voltage to the power supply module.
Table9.2 Immunity related standards
Test description
An electrostatic discharge is
applied to the enclosure of the
equipment.
An electric field is radiated to the
product.
Burst noise is applied to power
lines and signal lines.
Lightning surge is applied to
*1
power lines and signal lines.
High-frequency noise is applied
*1
to power lines and signal lines.
The product is immersed in the
magnetic field of an induction
*1
coil.
Power voltage is momentarily
interrupted.
* 1 : Programmable controller is an open type device (a device designed to be housed in other
equipment) and must be installed inside a conductive control panel. The tests were conducted
with the programmable controller installed in a control panel, applying the maximum applicable
input voltage to the power supply module.
* 2 : The accuracy of an analog-digital converter module may temporarily vary within ±10%.
9.1 Requirements for Conformance to EMC Directive
Value specified in standard
• 30 to 230MHz, QP: 40dBµV/m (measured at 10m
*1
distance)
• 230 to 1000MHz, QP: 47dBµV/m (measured at
10m distance)
• 0.15 to 0.5MHz, QP: 79dB,
Mean: 66dB
• 0.5 to 30MHz, QP: 73dB, Mean: 60dB
Value specified in standard
• 8kV Air discharge
• 4kV Contact discharge
80% AM modulation @1kHz
• 80 to 1000MHz: 10Vm
• 1.4 to 2.0GHz: 3Vm
• 2.0 to 2.7GHz: 1Vm
• AC/DC power, I/O power, and AC I/O (unshielded)
lines: 2kV
• DC I/O, analog, and communication lines: 1kV
• AC power, AC I/O power, and AC I/O (unshielded)
lines: 2kV CM, 1kV DM
• DC power and DC I/O power lines: 0.5kV CM,
0.5kV DM
• DC I/O, AC I/O (shielded), analog
communication lines: 1kV CM
0.15 to 80MHz, 80% AM modulation @1kHz, 10Vrms
50/60Hz, 30A/m
• 0%, 0.5 period, starting at zero-crossing
• 0%, 250/300 period (50/60Hz)
• 40%, 10/12 period (50/60Hz)
• 70%, 25/30 period (50/60Hz)
9.1.1 Standards relevant to the EMC Directive
*1
*2
, and
9
10
11
12
9
- 2