Safe Stop 1 (Ss1) - Siemens Sinamics S120 Function Manual

Hide thumbs Also See for Sinamics S120:
Table of Contents

Advertisement

3.1.2

Safe Stop 1 (SS1)

Definition according to EN 61800-5-2:
"The function SS1 brakes the motor and
trips the function STO after a delay time."
Ex ample of how the function can be used
Example
After an Emergency Stop button has been pressed,
the drive must be braked as quickly as possible and
brought into the STO state.
A central Emergency Stop button ensures that sev-
eral drives are braked as quickly as possible and
brought into the STO state.
How does SS1 function in detail?
Ov erview
The drive decelerates once "Safe Stop 1" has
been selected, and goes into the "Safe Torque
Off" state once the delay time has expired.
Select SS1
As soon as the converter identifies that SS1 has been selected via a terminal or via the
PROFIsafe safe communication, the following happens:
● If, when selecting SS1, the motor is already switched off, then until the SS1 delay time
expires, there is no response. STO becomes active after the time expires.
● If the motor is switched on when SS1 is selected, the inverter brakes the motor with the
OFF3 ramp-down time. After the delay time, STO is triggered automatically.
Safety Integrated
Function Manual, (FHS), 07/2016, 6SL3097-4AR00-0BP6
Overview of Safety Integrated functions
3.1 Safety Integrated Basic Functions
Po ssible solution
Wire the Emergency Stop button with a
fail-safe input.
Select SS1 via the fail-safe input.
Evaluating an emergency stop pushbutton
in a central control.
Select SS1 via PROFIsafe.
35