Dm Allocation And Contents - Omron SYSMAC C200H-AD003 Operation Manual

Analog i/o units
Hide thumbs Also See for SYSMAC C200H-AD003:
Table of Contents

Advertisement

IR and DM Areas

3-4-2 DM Allocation and Contents

DM Allocation
SYSMAC C200H/C200HS/C200HX/HG/HE PC
Data Memory (DM)
Unit #0
Unit #1
Unit #2
Unit #3
Unit #4
Unit #5
Unit #6
Unit #7
Unit #8
Unit #9
Unit #A
Unit #B
Unit #C
Unit #D
Unit #E
Unit #F
DM Allocation Contents
DM word
15
14
DM (m)
( )
Not used.
DM (m+1)
(
)
Output 8
DM (m+2)
Not used.
DM (m+3)
Not used.
DM (m+4)
Not used.
DM (m+5)
Not used.
DM (m+6)
Not used.
DM (m+7)
Not used.
DM (m+8)
Not used.
DM (m+9)
Not used.
DM words
DM 1000 to 1099
DM 1100 to 1199
Data is automatically
DM 1200 to 1299
transferred to each unit
DM 1300 to 1399
number when the power
is turned on, or when the
DM 1400 to 1499
Special I/O Unit Restart
Bit is turned ON.
DM 1500 to 1599
DM 1600 to 1699
DM 1700 to 1799
DM 1800 to 1899
DM 1900 to 1999
DM 2000 to 2099
DM 2100 to 2199
DM 2200 to 2299
DM 2300 to 2399
DM 2400 to 2499
DM 2500 to 2599
Note
1. Switches A to F can be set for the C200HX/HG-CPU5j-E/6j-E. Setting
numbers A to F for C200H, C200HS, C200HE, or C200HX/HG-
CPU3j-E/4j-E PCs will cause an I/O UNIT OVER error and the Unit will
not operate.
2. If two or more Special I/O Units are assigned the same unit number, an I/O
UNIT OVER error will be generated and operation will stop.
The following table shows the allocation of DM words and bits for both normal
and adjustment mode.
13
12
11
10
Output signal range setting (See note 1.)
Output 7
Output 6
Note
1. This setting is not valid for the C200H-DA004 (current output model). The
output signal range for the C200-DA004 is 4 to 20 mA, regardless of the set-
tings.
C200H-DA003/DA004 Analog Output Unit
Fixed data area
DM (m)
DM (m+1)
DM (m+2
to m+9)
m = 1000 + 100 x unit number
(Units #A to #F = Unit numbers 10 to 15)
Bits
9
8
7
6
8
7
Output 5
Output 4
Output 1: Output status when conversion stopped
Output 2: Output status when conversion stopped
Output 3: Output status when conversion stopped
Output 4: Output status when conversion stopped
Output 5: Output status when conversion stopped
Output 6: Output status when conversion stopped
Output 7: Output status when conversion stopped
Output 8: Output status when conversion stopped
Section
Use designation
Output signal
range setting
Output hold
function setting
5
4
3
2
Use designation outputs
6
5
4
3
Output 3
Output 2
3-4
1
0
2
1
Output 1
49