Transmitting a Test call
D
Testing on the exclusive DSC distress and safety calling chan-
nels should be avoided as much as possible. When testing on
a distress/safety channel is unavoidable, you should indicate
that these are test transmissions.
Normally the test call would require no further communica-
tions between the two stations involved.
Enter "TEST CALL" in the DSC CALLS menu.
q
DSC Calls
MENU
(Push [MENU])
(Rotate Dial, then push [ENT].)
Select a desired preprogrammed individual address, or
w
"Manual Input," then push Dial or [ENT].
• The ID code for the Individual call can be set irst. (p. 19)
• When "Manual Input" is selected, set the 9 digit MMSI ID code for
the individual you wish to call.
•Push [EXIT] to return to the normal operating mode.
•Push [BACK] to return to the previous screen.
Test Call
About Manual Inputting:
Enter a desired address ID in the following way:
• Select a desired number using Dial, or [Ω]/[≈].
• Push [ENT] or Dial to set it.
• To move the cursor, select either arrow, "←" or "→," then push
[ENT] or Dial.
• The irst digit is speciied as '0' for a Group ID. If a 9 digit Group ID
is entered, an error beep sounds when pushing [ENT] or dial.
• The irst two digits are '0' for any Coast station ID.
A confirmation screen appears.
e
• Conirm the call contents.