Omron CS1W-V680C11 User Manual page 129

V680 series, id sensor units
Table of Contents

Advertisement

 Write
Writes the specified number of bytes of data beginning at the specified start address in the RF Tag.
Up to 2,048 bytes (i.e., 1,024 words) can be written with one command execution.
Word address
Antenna 1 of
Antenna 2 of
CS1W-V680C11,
CS1W-V680C12
CS1W-V680C12,
CJ1W-V680C11,
CJ1W-V680C12
or CJ1W-V680C12
n+1
n+2
n+3
n+4
n+5
n+6
• Verification will not be performed if No Verification is set for writing.
• Check the memory capacity of the RF Tag before setting the Processing Address and Number of Processing Bytes. If
the Processing Address and Number of Processing Bytes are not suitable for the RF Tags for which communications
are being performed, the RF Tag Address Error Flag (CIO n+8, bit 13) will turn ON.
Bit No.
Type
or
08 to 15
04 t 07
n+11
Command
00 to 03
n+12
00 to 15
n+13
00 to 15
n+14
00 to 15
Data
12 to 15
storage
08 to 11
area
n+15
00 to 07
n+16
00 to 15
Option
Controlling the ID Sensor Unit
Bit name
Command code
01 hex
Communications
Specify the communications method with
Specification
the RF Tag.
p. 85
0 Trigger
1 Single auto
2 Repeat auto
3 FIFO trigger
4 FIFO repeat
5 Multi-access trigger
6 Multi-access repeat
Processing
Specify the write data storage order.
Specification
0 Leftmost → Rightmost
p. 70
1 Rightmost → Leftmost
Processing
Specify the first RF Tag address to write.
Address
Setting range: 0000 to FFFF hex
Number of
Specify number of RF Tag write bytes
Processing Bytes
Setting range: 0001 to 0800 hex
Data Storage
Specify the write data storage destination.
Word Address
p. 70
(rightmost 4 digits)
Data Storage Area
Bank Specification
Data Storage
Word Address
(leftmost 2 digits)
Command Option
0000 hex
SECTION 6
Description
RFID System
127
User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1w-v680c11Cj1w-v680c12Cs1w-v680c12